Abstract
Ferrous sulphate gel dosimetry has the potential for measurement of absorbed dose distributions in proton therapy. The chemical properties of the gel are altered according to the radiation dose and these changes can be evaluated in three dimensions using MRI. The purpose of this work was to investigate the properties of a ferrous gel used with clinical proton beams. The gel was irradiated with both monoenergetic and range-modulated proton beams. It was then evaluated using MRI. The depth dose by means of the 1/T1 distribution was studied and compared with data from a plane-parallel plate ionization chamber. 1/T1 was shown to be proportional to the dose at a mean proton energy of approximately 90 MeV. The dose response was no different from that obtained using photon beams. However, on normalization at the entrance, the relative 1/T1 at the Bragg peak was 15-20% lower than the corresponding ionization chamber data for the monoenergetic proton beam. Better agreement was found for the modulated beam, but with significant differences close to the distal edge of the 1/T1 distribution. The change in sensitivity with depth was explained by means of a linear energy transfer dependence. This property was further studied using Monte Carlo methods.This publication has 23 references indexed in Scilit:
- Improvements in absorbed dose measurements for external radiation therapy using ferrous dosimeter gel and MR imaging (FeMRI)Physics in Medicine & Biology, 1998
- Dose distribution of proton beams with NMR measurements of fricke-agarose gelsMagnetic Resonance Imaging, 1997
- Phantom dosimeters examined by NMR analysis: a promising technique for 3-D determination of absorbed doseApplied Radiation and Isotopes, 1997
- Precision, accuracy, and image plane uniformity in NMR relaxation time imaging on a 1.5 T whole-body MR imaging systemMagnetic Resonance Imaging, 1994
- A general solution to charged particle beam flattening using an optimized dual-scattering-foil technique, with application to proton therapy beamsPhysics in Medicine & Biology, 1994
- A spin-spin relaxation rate investigation of the gelatin ferrous sulphate NMR dosimeterPhysics in Medicine & Biology, 1994
- Current developments in proton therapy: a reviewPhysics in Medicine & Biology, 1993
- Nickel-Doped Agarose Gel Phantoms in MR ImagingActa Radiologica, 1991
- RLSQ: T1, T2, and ρ calculations, combining ratios and least squaresMagnetic Resonance in Medicine, 1987
- Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imagingPhysics in Medicine & Biology, 1984