Injection Laryngoplasty with Calcium Hydroxylapatite Gel Implant in an in Vivo Canine Model

Abstract
The ideal injectable agent for vocal fold medialization is biocompatible, durable, sized to prevent phagocytosis and migration, and formulated for easy injection and does not adversely affect the viscoelastic properties of the vocal fold. We tested a cohesive implant of calcium hydroxylapatite (CaHA) particles in a gel carrier in an in vivo canine model of phonation. Six dogs underwent unilateral recurrent laryngeal nerve section and injection laryngoplasty of the paralyzed vocal fold with a CaHA implant. The six follow-up examinations were performed at 1,2, 3, 6, 9, and 12 months, and the larynx and bilateral neck lymphatic system were harvested for histologic analysis. The CaHA implant adequately medialized the vocal fold to regain glottal closure. The mucosal waves remained unaltered from baseline. The implant remained soft in the larynx and did not migrate to the neck lymphatic system. A localized foreign body giant cell reaction was present on histologic evaluation, but not acute or other chronic inflammation. A size analysis revealed no resorption of the CaHA particles. A decrease in medialization was noted at all follow-up intervals related to resorption of the aqueous-based gel carrier. The CaHA implant appears to be relatively safe and suitable for injection laryngoplasty.