Quadrature surface MRI/MRS detectors comprised of circular loop and figure-8 or butterfly-shaped coils offer improved signal-to-noise-ratios (SNR) compared to single surface coils, and reduced power and specific absorption rates (SAR) when used for MRI excitation. While the radius of the optimum loop coil for performing MRI at depth d in a sample is known, the optimum geometry for figure-8 and butterfly coils is not. The geometries of figure-8 and square butterfly detector coils that deliver the optimum SNR are determined numerically by the electromagnetic method of moments. Figure-8 and loop detectors are then combined to create SNR-optimized quadrature detectors whose theoretical and experimental SNR performance are compared with a novel quadrature detector comprised of a strip and a loop, and with two overlapped loops optimized for the same depth at 3 T. The quadrature detection efficiency and local SAR during transmission for the three quadrature configurations are analyzed and compared. The SNR-optimized figure-8 detector has loop radius r 8 ~ 0.6d, so r 8/r 0 ~ 1.3 in an optimized quadrature detector at 3 T. The optimized butterfly coil has side length ~ d and crossover angle of ≥50° at the center. These new design rules for figure-8 and butterfly coils optimize their performance as linear and quadrature detectors.Keywords
This publication has 18 references indexed in Scilit:
- Optimizing the intrinsic signal‐to‐noise ratio of MRI strip detectorsMagnetic Resonance in Medicine, 2006
- A method for preamplifier‐decoupling improvement in quadrature phased‐array coilsJournal of Magnetic Resonance Imaging, 2004
- Lumped‐element planar strip array (LPSA) for parallel MRIMagnetic Resonance in Medicine, 2003
- Magnetic resonance imaging can cause focal heating in a nonuniform phantomIEEE Transactions on Biomedical Engineering, 1993
- Homogeneous Tissue Model Estimates of RF Power Deposition in Human NMR StudiesAnnals of the New York Academy of Sciences, 1992
- Proton‐decoupled, overhauser‐enhanced, spatially localized carbon‐13 spectroscopy in humansMagnetic Resonance in Medicine, 1989
- Quadrature detection surface coilMagnetic Resonance in Medicine, 1987
- Quadrature rf coil pairsMagnetic Resonance in Medicine, 1986
- Comparison of linear and circular polarization for magnetic resonance imagingJournal of Magnetic Resonance (1969), 1985
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978