Fast slice‐selective radio‐frequency excitation pulses for mitigating B inhomogeneity in the human brain at 7 Tesla
Open Access
- 27 May 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (6), 1355-1364
- https://doi.org/10.1002/mrm.21585
Abstract
A novel radio‐frequency (RF) pulse design algorithm is presented that generates fast slice‐selective excitation pulses that mitigate B inhomogeneity present in the human brain at high field. The method is provided an estimate of the B field in an axial slice of the brain and then optimizes the placement of sinc‐like “spokes” in k z via an L1‐norm penalty on candidate (k x , k y ) locations; an RF pulse and gradients are then designed based on these weighted points. Mitigation pulses are designed and demonstrated at 7T in a head‐shaped water phantom and the brain; in each case, the pulses mitigate a significantly nonuniform transmit profile and produce nearly uniform flip angles across the field of excitation (FOX). The main contribution of this work, the sparsity‐enforced spoke placement and pulse design algorithm, is derived for conventional single‐channel excitation systems and applied in the brain at 7T, but readily extends to lower field systems, nonbrain applications, and multichannel parallel excitation arrays. Magn Reson Med 59:1355–1364, 2008.This publication has 28 references indexed in Scilit:
- Advanced three‐dimensional tailored RF pulse for signal recovery in T2*‐weighted functional magnetic resonance imagingMagnetic Resonance in Medicine, 2006
- Parallel RF transmission with eight channels at 3 TeslaMagnetic Resonance in Medicine, 2006
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channelsMagnetic Resonance in Medicine, 2005
- Measurement and correction of transmitter and receiver induced nonuniformities in vivoMagnetic Resonance in Medicine, 2005
- 3-D FLASH Imaging Using a Single Surface Coil and a New Adiabatic Pulse, BIR-4Investigative Radiology, 1990
- A k-space analysis of small-tip-angle excitationJournal of Magnetic Resonance (1969), 1989
- Spectroscopy and imaging with a 4 tesla whole‐body mr systemNMR in Biomedicine, 1988
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978
- The signal-to-noise ratio of the nuclear magnetic resonance experimentJournal of Magnetic Resonance (1969), 1976