A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field
- 22 May 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (12), 3563-3578
- https://doi.org/10.1088/0031-9155/52/12/015
Abstract
Existing studies have suggested some debate on whether the quality of radiation that delivers dose outside of the primary field of a radiotherapy photon beam can be considered the same as that inside the primary field. We used a Monte Carlo approach to simulate the electron fluence differential in energy inside a water phantom in response to irradiation by a 6 MV photon beam. The goal was to quantify how significantly the electron fluence changes when moving from a volume exposed to the primary field to one outside of the primary field, and understand any potential biological implications. We scored the electron fluence outwards in annular volumes in response to a 5 cm radius 6 MV beam and at the central axis in response to a rectangular 6 MV beam partially blocked by an MLC. The resulting fluence spectra were compared to different low-LET sources for which biological response in the form of chromosomal aberrations has been published. Our results show a significant increase in the low energy component of the fluence spectra outside of the primary field, which increases the mean LET to values similar to that seen in response to a 137Cs photon source. In turn, it is shown that this has the potential to increase the RBE.Keywords
This publication has 13 references indexed in Scilit:
- The variation in biological effectiveness of X-rays and gamma rays with energyRadiation Protection Dosimetry, 2004
- RADIATION QUALITY OF A TOMOTHERAPY PHOTON FAN BEAMHealth Physics, 2004
- Electron Spectra and the RBE of X RaysRadiation Research, 2002
- An investigation of energy spectrum and lineal energy variations in mega-voltage photon beams used for radiotherapy.Radiation Protection Dosimetry, 2002
- Mutagenicity of low-filtered 30 kVp X-rays, mammography X-rays and conventional X-rays in cultured mammalian cellsInternational Journal of Radiation Biology, 2002
- High-dose spatially-fractionated radiation (GRID): a new paradigm in the management of advanced cancersInternational Journal of Radiation Oncology*Biology*Physics, 1999
- BEAM: A Monte Carlo code to simulate radiotherapy treatment unitsMedical Physics, 1995
- The effect of 220 kVp X-rays with different spectra on the dose response of chromosome aberrations in human lymphocytesRadiation and Environmental Biophysics, 1984
- Calculated yields and slowing-down spectra for electrons in liquid water: implications for electron and photon RBEPhysics in Medicine & Biology, 1978
- Water/air mass stopping power ratios for megavoltage photon and electron beamsPhysics in Medicine & Biology, 1978