The certification of Standard Reference Material (SRM is a registered trademark of NIST) 3103a As Spectrometric Solution is based on the gravimetric preparation value that is verified by inductively coupled plasma optical emission spectrometry (ICP-OES) measurements. A disagreement between the gravimetric and the spectrometric values for a batch of As calibration solutions led to the discovery that the solutions contained a mixture of trivalent and pentavalent As species and that the pentavalent species was ∼8% more sensitive than the trivalent species with ICP-OES determination. The kinetics of the reaction between As metal and nitric acid were studied, and the results were applied to develop a procedure that would consistently produce single-species pentavalent As standards, which eliminates As speciation as a source of measurement bias in the SRM certification process.Keywords
This publication has 10 references indexed in Scilit:
- Single-Element Solution Comparisons with a High-Performance Inductively Coupled Plasma Optical Emission Spectrometric MethodAnalytical Chemistry, 2001
- An approach to combining results from multiple methods motivated by the ISO GUMJournal of Research of the National Institute of Standards and Technology, 2000
- High-speed separation of arsenic compounds using narrow-bore high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2000
- A Drift Correction ProcedureAnalytical Chemistry, 1998
- Ultrasonic nebulization and arsenic valence state considerations prior to determination via inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1995
- Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciationJournal of Analytical Atomic Spectrometry, 1994
- ‘Zone model’ as an explanation for signal behaviour and non-spectral interferences in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1993
- Separation of arsenic species by ion-pair and ion exchange high performance liquid chromatographyMicrochimica Acta, 1992
- Recommended Inorganic Chemicals for CalibrationAnalytical Chemistry, 1988
- Utilization of ultrasonic nebulization of atomic absorption spectrometry. ParametersAnalytical Chemistry, 1975