Abstract
We develop and validate a Modified Beer-Lambert law for blood flow based on diffuse correlation spectroscopy (DCS) measurements. The new formulation enables blood flow monitoring from temporal intensity autocorrelation function data taken at single or multiple delay-times. Consequentially, the speed of the optical blood flow measurement can be substantially increased. The scheme facilitates blood flow monitoring of highly scattering tissues in geometries wherein light propagation is diffusive or non-diffusive, and it is particularly well-suited for utilization with pressure measurement paradigms that employ differential flow signals to reduce contributions of superficial tissues.Keywords
Funding Information
- American Heart Association (AHA) (14POST20460161)
- National Institutes of Health (NIH) (8P41-EB015893, NHLBI-HL007915, R01-NS060653)
- Sao Paulo Research Foundation (FAPESP) (2012/02500-8, 2013/07559-3)
This publication has 81 references indexed in Scilit:
- Optical Characterization of Two-Layered Turbid Media for Non-Invasive, Absolute Oximetry in Cerebral and Extracerebral TissuePLOS ONE, 2013
- Absolute measurement of cerebral optical coefficients, hemoglobin concentration and oxygen saturation in old and young adults with near-infrared spectroscopyJournal of Biomedical Optics, 2012
- Near-infrared diffuse correlation spectroscopy in cancer diagnosis and therapy monitoringJournal of Biomedical Optics, 2012
- The use of muscle near-infrared spectroscopy in sport, health and medical sciences: recent developmentsPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- Has the time come to use near-infrared spectroscopy as a routine clinical tool in preterm infants undergoing intensive care?Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- Haemoglobin oxygen saturation as a biomarker: the problem and a solutionPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- Direct measurement of tissue blood flow and metabolism with diffuse opticsPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- Frontal cerebral cortex blood flow, oxygen delivery and oxygenation during normoxic and hypoxic exercise in athletesThe Journal of Physiology, 2011
- Mapping of cerebral oxidative metabolism with MRIProceedings of the National Academy of Sciences of the United States of America, 2010