Correlation Between Low Triggered Electromyographic Thresholds and Lumbar Pedicle Screw Malposition
- 1 November 2007
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Spine
- Vol. 32 (24), 2673-2678
- https://doi.org/10.1097/brs.0b013e31815a524f
Abstract
A retrospective analysis of 1078 spinal surgical procedures with lumbar pedicle screw placement at a single institution. Based on previously established normative values, triggered electromyographic stimulation (TrgEMG) was re-examined to evaluate its efficacy in determining screw malposition. Threshold values for confirmation of intraosseous placement of pedicle screws with EMG stimulation is controversial. TrgEMG threshold values for 4857 pedicle screws placed from L2 to S1 from 1996 to 2005 were analyzed. An ascending method of constant current stimulation was applied to each pedicle screw to obtain a compound muscle action potential (CMAP) from lower extremity myotomes. Previously determined threshold value normative data from a published clinical series of 233 screws were as follows: 0 to 4 mA, high likelihood of pedicle wall breach; 4 to 8 mA, possible pedicle wall breach; >8 mA, no pedicle wall defect. A total of 7.74% (376 of 4857) of all screws tested had threshold values 8.0 mA, 17.4% for 4.0 to 8.0 mA, 54.2% for <4.0 mA, and 100% for <2.8 mA. At 2.8 mA, triggered EMG has a specificity of 100%, with sensitivity of 8.4%; at 4.0 mA, specificity of 99% and sensitivity of 36%; and at 8.0 mA, 94% specificity and 86% sensitivity. TrgEMG is an adjunct technique and should always be used in conjunction with palpation and radiography to optimize safe pedicle screw placement.Keywords
This publication has 24 references indexed in Scilit:
- Probing for Thoracic Pedicle Screw Tract Violation(s)Journal of Spinal Disorders & Techniques, 2004
- Neurophysiologic Monitoring of Spinal Nerve Root Function During Instrumented Posterior Lumbar Spine SurgerySpine, 2002
- A New Method for Detecting Pedicular Wall Perforation During Pedicle Screw InsertionSpine, 2001
- Radiographic Verification of Pedicle Screw Pilot Hole Placement Using Kirshner Wires Versus Beaded WiresSpine, 1999
- Complications of Pediatric Thoracolumbar and Lumbar Pedicle ScrewsSpine, 1998
- Improved Accuracy of Pedicle Screw Insertion With Computer-Assisted SurgerySpine, 1997
- Triggered Electromyographic Threshold for Accuracy of Pedicle Screw PlacementSpine, 1995
- Pedicle Screw Placement With Intraosseous EndoscopySpine, 1994
- Complications Associated with the Technique of Pedicle Screw Fixation A Selected Survey of ABS MembersSpine, 1993
- Intraoperative Evoked EMG Monitoring in an Animal ModelSpine, 1992