Feasibility of 7 Tesla Breast Magnetic Resonance Imaging Determination of Intrinsic Sensitivity and High-Resolution Magnetic Resonance Imaging, Diffusion-Weighted Imaging, and 1H-Magnetic Resonance Spectroscopy of Breast Cancer Patients Receiving Neoadjuvant Therapy
- 1 June 2011
- journal article
- clinical trial
- Published by Ovid Technologies (Wolters Kluwer Health) in Investigative Radiology
- Vol. 46 (6), 370-376
- https://doi.org/10.1097/rli.0b013e31820df706
Abstract
To evaluate the feasibility of 7T breast magnetic resonance imaging (MRI) by determining the intrinsic sensitivity gain compared with 3T in healthy volunteers and to explore clinical application of 7T MRI in breast cancer patients receiving neoadjuvant chemotherapy (NAC). In 5 volunteers, the signal-to-noise ratio (SNR) was determined on proton density MRI at 3T using a conventional 4-channel bilateral breast coil and at 7T using a dedicated 2-channel unilateral breast coil, both obtained at identical scan parameters. Subsequently, consecutive breast cancer patients on NAC were included. The 7T breast MRI protocol consisted of diffusion-weighted imaging, 3D high-resolution (450 μm isotropic) T1-weighted fat-suppressed gradient-echo sequences and quantified single voxel (1)H-magnetic resonance spectroscopy. Morphology was scored according to the MRI Breast Imaging-Reporting and Data System (BI-RADS)-lexicon, and the images were compared with 3T and histopathologic findings. Image quality was evaluated using a 5-point scale. A 5.7-fold higher SNR was measured at 7T than at 3T, which reflects the advantages of a higher field strength and the use of optimized radiofrequency coils. Three breast cancer patients were included and received a total of 13 7T MRI examinations. The image quality of the high-resolution examinations was at least satisfactory, and good to excellent in 9 of the 13 examinations performed. More anatomic detail was depicted at 7T than at 3T. In 1 case, a fat plane between the muscle and tumor was visible at 7T, but not at the clinically performed 3T examination, suggesting that there was no muscle invasion, which was confirmed by pathology. Changes in tumor apparent diffusion coefficient values could be monitored in 2 patients and were found to increase during NAC, consistent with published results from studies at lower field strengths. Apparent diffusion coefficient values increased respectively from 0.33 × 10(-3) mm(2)/s to 1.78 × 10(-3) mm(2)/s after NAC and from 1.20 × 10(-3) mm(2)/s to 1.44 × 10(-3) mm(2)/s during NAC. Choline concentrations as low as 0.77 mMol/kg(water) could be detected. In 1 patient, choline levels showed an overall decrease from 4.2 mMol/kw(water) to 2.6 mMol/kg(water) after NAC and the tumor size decreased correspondingly from 3.9 × 4.1 × 5.6 cm(3) to 2.0 × 2.7 × 2.4 cm(3). All 7T MRI findings were consistent with pathology analysis. Dedicated 7T breast MRI is technically feasible, can provide more SNR than at 3T, and has diagnostic potential.Keywords
This publication has 24 references indexed in Scilit:
- Magnetic resonance imaging of the breast: Recommendations from the EUSOMA working groupEuropean Journal Of Cancer, 2010
- Handling a High Relaxivity Contrast Material for Dynamic Breast MR Imaging Using Higher Thresholds for the Initial EnhancementInvestigative Radiology, 2010
- Clinical implementation of a multislice high spectral and spatial resolution-based MRI sequence to achieve unilateral full-breast coverageMagnetic Resonance Imaging, 2010
- Improved signal to noise in proton spectroscopy of the human calf muscle at 7 T using localized B1 calibrationMagnetic Resonance in Medicine, 2009
- The Challenge of Imaging Dense Breast ParenchymaInvestigative Radiology, 2009
- Predicting Pathologic Response to Neoadjuvant Chemotherapy in Breast Cancer by Using MR Imaging and Quantitative1H MR SpectroscopyRadiology, 2009
- Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurementsMagnetic Resonance in Medicine, 2008
- Short echo time 1H‐MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulsesMagnetic Resonance in Medicine, 2007
- Metabolite quantification and high‐field MRS in breast cancerNMR in Biomedicine, 2007
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006