Magnetic resonance imaging of the upper abdomen using a free‐breathing T2‐weighted turbo spin echo sequence with navigator triggered prospective acquisition correction
- 15 April 2005
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (5), 576-582
- https://doi.org/10.1002/jmri.20293
Abstract
Purpose To evaluate a free‐breathing navigator triggered T2‐weighted turbo spin‐echo sequence with prospective acquisition correction (T2w‐PACE‐TSE) for MRI of the upper abdomen in comparison to a conventional T2‐weighted TSE (T2w‐CTSE), a single‐shot TSE (T2w‐HASTE), and a T1‐weighted gradient‐echo sequence (T1w‐FLASH). Materials and Methods A total of 40 consecutive patients were examined at 1.5 T using free‐breathing T2w‐PACE‐TSE, free‐breathing T2w‐CTSE, and breath‐hold T2w‐HASTE and T1w‐FLASH acquisition. Images were evaluated qualitatively by three radiologists regarding motion artifacts, liver‐spleen contrast, depiction of intrahepatic vessels, the pancreas and the adrenal glands, and overall image quality on a four‐point scale. Quantitative analysis of the liver‐spleen contrast was performed. Results Depiction and sharpness of intrahepatic vessels were rated significantly better (P < 0.01) using T2w‐PACE‐TSE compared to T2w‐CTSE and T2w‐HASTE sequences. Significantly higher contrast values were measured for T2w‐PACE‐TSE images compared to T2w‐CTSE, T2w‐HASTE, and T1w‐FLASH images (P < 0.01). Mean examination time of the T2w‐PACE‐TSE was 7.91 minutes, acquisition time of the T2w‐CTSE sequence was 4.52 minutes. Conclusion Prospective acquisition correction is an efficient method for reducing respiratory movement artifacts in T2w‐TSE imaging of the upper abdomen. Compared to T2w‐CTSE and T2w‐HASTE sequences recognition of anatomical details and contrast can be significantly improved. J. Magn. Reson. Imaging 2005;21:576–582.This publication has 27 references indexed in Scilit:
- HASTE MR imaging: Description of technique and preliminary results in the abdomenJournal of Magnetic Resonance Imaging, 1996
- Comparison of single-breath-hold fast spin-echo sequences with routine non-breath-hold techniques: Application to MRI of renal massesJournal of Magnetic Resonance Imaging, 1996
- Optimizing fast spin echo acquisitions for hepatic imaging in normal subjectsJournal of Magnetic Resonance Imaging, 1996
- Echoplanar MR imaging of the liver in patients with focal hepatic lesions: quantitative analysis of images made with various pulse sequences.American Journal of Roentgenology, 1994
- A new T2 preparation technique for ultrafast gradient‐echo sequenceMagnetic Resonance in Medicine, 1994
- Fast spin‐echo MR imaging of the abdomen: Contrast optimization and artifact reductionJournal of Magnetic Resonance Imaging, 1994
- Hybrid RARE: Implementations for abdominal MR imagingJournal of Magnetic Resonance Imaging, 1994
- Improving MR image quality in the presence of motion by using rephasing gradientsAmerican Journal of Roentgenology, 1987
- Respiratory Ordered Phase Encoding (ROPE)Journal of Computer Assisted Tomography, 1985
- Selective Saturation NMR ImagingJournal of Computer Assisted Tomography, 1984