Exogenous contrast agent improves sensitivity of gradient‐echo functional magnetic resonance imaging at 9.4 T
Open Access
- 23 November 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (6), 1272-1281
- https://doi.org/10.1002/mrm.20278
Abstract
Relative to common clinical magnetic field strengths, higher fields benefit functional brain imaging both by providing additional signal for high‐resolution applications and by improving the sensitivity of endogenous contrast due to the blood oxygen level dependent (BOLD) mechanism, which has limited detection power at low magnetic fields relative to the use of exogenous contrast agent. This study evaluates the utility of iron oxide contrast agent for gradient echo functional MRI at 9.4 T in rodents using cocaine and methylphenidate as stimuli. Relative to the BOLD method, the use of high iron doses and short echo times provided a roughly twofold global increase in functional sensitivity, while also suppressing large vessel signal and reducing susceptibility artifacts. Furthermore, MRI measurements of the functional percentage change in cerebral blood volume (CBV) showed excellent agreement with results obtained at much lower magnetic field strengths, demonstrating that MRI estimates of this quantity are roughly independent of magnetic field when appropriate techniques are employed. The derived field dependencies for relative sensitivity and MRI estimates of the percentage change in CBV suggest that the benefits provided by exogenous agents will persist even at much higher magnetic fields than 9.4 T. Magn Reson Med 52:1272–1281, 2004.Keywords
This publication has 25 references indexed in Scilit:
- Correlation between Brain Reorganization, Ischemic Damage, and Neurologic Status after Transient Focal Cerebral Ischemia in Rats: A Functional Magnetic Resonance Imaging StudyJournal of Neuroscience, 2003
- High-Field Magnetic ResonancePublished by Elsevier BV ,2002
- Improved mapping of pharmacologically induced neuronal activation using the IRON technique with superparamagnetic blood pool agentsJournal of Magnetic Resonance Imaging, 2001
- Functional magnetic resonance imaging of reorganization in rat brain after strokeProceedings of the National Academy of Sciences of the United States of America, 2001
- Functional recovery after brain lesion???contralateral neuromodulation: an fMRI studyNeuroReport, 2001
- Regional sensitivity and coupling of BOLD and CBV changes during stimulation of rat brainMagnetic Resonance in Medicine, 2001
- Detection of the effects of dopamine receptor supersensitivity using pharmacological MRI and correlations with PETSynapse, 2000
- Cocaine Activation Discriminates Dopaminergic Projections by Temporal Response: An fMRI Study in RatNeuroImage, 2000
- Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulationMagnetic Resonance in Medicine, 1998
- Experimental determination of the BOLD field strength dependence in vessels and tissueMagnetic Resonance in Medicine, 1997