Abstract
An RF excitation scheme is presented for anatomical imaging of occipital brain areas at 3T using the 3D modified driven equilibrium Fourier transform (MDEFT) sequence and a transmit‐receive surface coil. Surface coils operated in the transmit mode usually display a high B1 inhomogeneity. This causes variations of the flip angle and impairs fat saturation, resulting in blurring, signal losses, and artifacts due to high scalp intensities. A composite binomial pulse with one spectral component for water selective excitation and one spatial component for B1 inhomogeneity compensation is presented. It is shown experimentally that the pulse prevents image blurring and reduces the scalp signal considerably. The total pulse duration of only 2.4 ms is compatible with the relatively short repetition times (TRs) required for MDEFT imaging. The method is particularly useful for certain applications in neuroimaging that require technical equipment that is too large for standard coils or should not be exposed to RF fields. Magn Reson Med 53:1212–1216, 2005.Keywords
This publication has 18 references indexed in Scilit:
- Active deep brain stimulation during MRI: A feasibility studyMagnetic Resonance in Medicine, 2004
- Optimisation of the 3D MDEFT sequence for anatomical brain imaging: technical implications at 1.5 and 3 TNeuroImage, 2003
- Simultaneous highly selective MR water and fat imaging using a simple new type of spectral‐spatial excitationMagnetic Resonance in Medicine, 1998
- Highly selective water and fat imaging applying multislice sequences without sensitivity to B1 field inhomogeneitiesMagnetic Resonance in Medicine, 1997
- Adiabatic Slice-Selective Excitation for Surface CoilsJournal of Magnetic Resonance, 1997
- Adiabatic rf pulses: Applications toin vivo NMRConcepts in Magnetic Resonance, 1997
- B1-Insensitive, Single-Shot Localization and Water SuppressionJournal of Magnetic Resonance, Series B, 1996
- Single‐shot, B1‐insensitive slice selection with a gradient‐modulated adiabatic pulse, BISS‐8Magnetic Resonance in Medicine, 1996
- 3-D FLASH Imaging Using a Single Surface Coil and a New Adiabatic Pulse, BIR-4Investigative Radiology, 1990
- In vivo nuclear magnetic resonance chemical shift imaging by selective irradiation.Proceedings of the National Academy of Sciences of the United States of America, 1984