Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.
Open Access
- 31 August 2010
- journal article
- clinical trial
- Published by Springer Science and Business Media LLC in BMC Musculoskeletal Disorders
- Vol. 11 (1), 194
- https://doi.org/10.1186/1471-2474-11-194
Abstract
Background: The aims of this study were to evaluate the construct validity (known group), concurrent validity (criterion based) and test-retest (intra-rater) reliability of manual goniometers to measure passive hip range of motion (ROM) in femoroacetabular impingement patients and healthy controls.Methods: Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS) on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study.Results: The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees;P< 0.001); good concurrent validity was only achieved for hip abduction and internal rotation, with intraclass correlation coefficients (ICC) of 0.94 and 0.88, respectively. Both devices detected lower hip abduction ROM in patients compared to controls (P< 0.01). Test-retest reliability was good with ICCs higher 0.90, except for hip adduction (0.82-0.84). Reliability estimates did not differ between the goniometer and the ETS.Conclusions: The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion) rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.Keywords
This publication has 47 references indexed in Scilit:
- Clinical Presentation of Patients with Symptomatic Anterior Hip ImpingementClinical Orthopaedics & Related Research, 2009
- The Concept of Femoroacetabular Impingement: Current Status and Future PerspectivesClinical Orthopaedics & Related Research, 2009
- Measurement of Hip Range of Flexion-Extension and Straight-leg RaisingClinical Orthopaedics and Related Research, 2008
- Range of Motion in Anterior Femoroacetabular ImpingementClinical Orthopaedics & Related Research, 2007
- Noninvasive three‐dimensional assessment of femoroacetabular impingementJournal of Orthopaedic Research, 2006
- Femoroacetabular impingement caused by a femoral osseous head–neck bump deformity: clinical, radiological, and experimental resultsJournal of Orthopaedic Science, 2004
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- ISB recommendations for standardization in the reporting of kinematic dataJournal of Biomechanics, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part Icclm, 1983