Test-Retest Reliability and Minimal Detectable Change Scores for the Timed “Up & Go” Test, the Six-Minute Walk Test, and Gait Speed in People With Alzheimer Disease
Top Cited Papers
Open Access
- 1 June 2009
- journal article
- Published by Oxford University Press (OUP) in PTJ: Physical Therapy & Rehabilitation Journal
- Vol. 89 (6), 569-579
- https://doi.org/10.2522/ptj.20080258
Abstract
Background: With the increasing incidence of Alzheimer disease (AD), determining the validity and reliability of outcome measures for people with this disease is necessary. Objective: The goals of this study were to assess test-retest reliability of data for the Timed “Up & Go” Test (TUG), the Six-Minute Walk Test (6MWT), and gait speed and to calculate minimal detectable change (MDC) scores for each outcome measure. Performance differences between groups with mild to moderate AD and moderately severe to severe AD (as determined by the Functional Assessment Staging [FAST] scale) were studied. Design: This was a prospective, nonexperimental, descriptive methodological study. Methods: Background data collected for 51 people with AD included: use of an assistive device, Mini-Mental Status Examination scores, and FAST scale scores. Each participant engaged in 2 test sessions, separated by a 30- to 60-minute rest period, which included 2 TUG trials, 1 6MWT trial, and 2 gait speed trials using a computerized gait assessment system. A specific cuing protocol was followed to achieve optimal performance during test sessions. Results: Test-retest reliability values for the TUG, the 6MWT, and gait speed were high for all participants together and for the mild to moderate AD and moderately severe to severe AD groups separately (intraclass correlation coefficients ≥.973); however, individual variability of performance also was high. Calculated MDC scores at the 90% confidence interval were: TUG=4.09 seconds, 6MWT=33.5 m (110 ft), and gait speed=9.4 cm/s. The 2 groups were significantly different in performance of clinical tests, with the participants who were more cognitively impaired being more physically and functionally impaired. Limitations: A single researcher for data collection limited sample numbers and prohibited blinding to dementia level. Conclusions: The TUG, the 6MWT, and gait speed are reliable outcome measures for use with people with AD, recognizing that individual variability of performance is high. Minimal detectable change scores at the 90% confidence interval can be used to assess change in performance over time and the impact of treatment.Keywords
This publication has 39 references indexed in Scilit:
- Exercise Training is Beneficial for Alzheimer's PatientsInternational Journal of Sports Medicine, 2008
- 2008 Alzheimer's disease facts and figuresAlzheimer's & Dementia, 2008
- VALIDITY AND RELIABILITY OF QUANTITATIVE GAIT ANALYSIS IN GERIATRIC PATIENTS WITH AND WITHOUT DEMENTIAJournal of the American Geriatrics Society, 2007
- Exercise Program for Nursing Home Residents with Alzheimer's Disease: A 1‐Year Randomized, Controlled TrialJournal of the American Geriatrics Society, 2007
- Timed “Up & Go” Test: Reliability in Older People Dependent in Activities of Daily Living— Focus on Cognitive StatePTJ: Physical Therapy & Rehabilitation Journal, 2006
- Interpreting Change Scores of Tests and Measures Used in Physical TherapyPTJ: Physical Therapy & Rehabilitation Journal, 2006
- A preliminary study on the reliability of physical performance measures in older day-care center clients with dementia.International Psychogeriatrics, 2002
- Interrater Reliability of the Clinical Dementia Rating in a Multicenter TrialJournal of the American Geriatrics Society, 2000
- Feasibility and measurement properties of the functional reach and thetimed up and go tests in the Canadian study of health and agingThe Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 2000
- Reliability of Physical Performance Measures in Nursing Home Residents With Alzheimer's DiseaseThe Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 1997