Critical Review of Burn Depth Assessment Techniques: Part II. Review of Laser Doppler Technology
- 1 January 2010
- journal article
- review article
- Published by Oxford University Press (OUP) in Journal of Burn Care & Research
- Vol. 31 (1), 151-157
- https://doi.org/10.1097/bcr.0b013e3181c7ed60
Abstract
The judgment of which wounds are expected to heal within 21 days is one of the most difficult and important tasks of the burn surgeon. The quoted accuracy of 64 to 76% by senior burn surgeons underscores the importance of an adjunct technology to help make this determination. A plethora of techniques have been developed in the last 70 years. Laser Doppler imaging (LDI) is one of the most recent and widely studied of these techniques. The technology provides an estimate of perfusion through the burn wound, the assumption being that a lower perfusion correlates with a deeper wound and, therefore, a longer time to heal. Although some reports suggest accuracy between 96 and 100% and that it does this 2 days ahead of clinical judgment, others have questioned its applicability to clinical practice. This article, the second of a two-part series, has two objectives: 1) a review of the Doppler principle and how the LDI uses it to estimate perfusion; and 2) a critical assessment of the burn literature on the LDI. Part I provides a historical perspective of the different technologies used through the last 70 years to assist in the determination of burn depth. Laser Doppler has brought technology closer to provide a reliable adjuvant to the clinical prediction of healing, yet, caution is warranted. A clear understanding of the limitations of LDI is needed to put the current research in perspective to find the right clinical application for LDI.Keywords
This publication has 38 references indexed in Scilit:
- Using ordinal logistic regression to evaluate the performance of laser-Doppler predictions of burn-healing timeBMC Medical Research Methodology, 2009
- Infrared thermography: Experience from a decade of pediatric imagingEuropean Journal of Pediatrics, 2007
- Burn depths evaluation based on active dynamic IR thermal imaging—A preliminary studyBurns, 2006
- Laser Doppler Imaging of paediatric burns: Burn wound outcome can be predicted independent of clinical examinationBurns, 2006
- Skin blood flow pattern in burns outcomesBurns, 2004
- The Influence of Probe Fiber Distance on Laser Doppler Perfusion Monitoring MeasurementsMicrocirculation, 2003
- A note on the compartmental analysis and related issues in laser Doppler flowmetryIEEE Transactions on Biomedical Engineering, 1998
- Laser Doppler imaging of skin microcirculationActa Dermato-Venereologica, 1998
- New laser doppler scanner, a valuable adjunct in burn depth assessmentBurns, 1993
- A laser Doppler scanner for imaging blood flow in skinJournal of Biomedical Engineering, 1991