The laboratory calibration of a soil moisture capacitance probe in sandy soils
Open Access
- 1 January 2020
- journal article
- research article
- Published by Czech Academy of Agricultural Sciences in Soil and Water Research
- Vol. 15 (2), 75-84
- https://doi.org/10.17221/227/2018-SWR
Abstract
Determining and mitigating landslide risk is a technical-scientific objective, particularly for the protection and proper territorial management and planning. The slope stability depends on the pore pressure distribution, which is influenced by the saturation front propagation through the unsaturated zone, whose monitoring is useful to understand any possible instabilities. Such monitoring may be undertaken by sensors based on the measurement of the relative dielectric permittivity. Reliable relationships between the measurement and the soil moisture are necessary. The main objective of this study is to assess a laboratory calibration protocol for a specific capacitance sensor (Drill & Drop, Sentek Sensor Technologies). Two monogranular sands have been selected for the calibration purpose. The laboratory tests were performed under three relative density values (D-R equal to 40%, 60% and 80%) for seven volumetric water content values (theta(v) ranging from 0.00% to 36.26%). Based on the experimental measurements, the soil-specific calibration curves were determined at an assigned relative density value; in particular, a simple power law is adopted to describe the probe's reading as a function of the volumetric water content. The results point out that the relative density values slightly affect the tests, thus, the soil-specific calibration curves are derived based on a simple regression analysis fitting the whole set of the laboratory tests validated for each sand. The calculated coefficient of determination (R-2 = 0.96 divided by 0.99) and root mean square error (RMSE = 1.4%divided by 2.8%) values confirm the goodness of fit. In order to propose more general fitting curves, suitable for both the investigated sands, multiple linear regressions are performed by considering theta(v) and the mean grain size, D-50 as independent variables; again, the R-2 and RMSE values equal to 0.97 and 2.41%, respectively, confirm the suitability of the calibration curve. Finally, the laboratory calibration curves are compared with the manufacturer-supplied curves, thus, enhancing the need for the soil-specific calibration.Keywords
This publication has 14 references indexed in Scilit:
- Calibration of Capacitance Sensors for Compacted Silt in Non-Isothermal ApplicationsGeotechnical Testing Journal, 2016
- Assessing Field and Laboratory Calibration Protocols for the Diviner 2000 Probe in a Range of Soils with Different TexturesJournal of Irrigation and Drainage Engineering, 2016
- Hydrological factors affecting rainfall-induced shallow landslides: From the field monitoring to a simplified slope stability analysisEngineering Geology, 2015
- An Integrated Hydrological-Geotechnical Model in GIS for the Analysis and Prediction of Large-Scale Landslides Triggered by Rainfall EventsPublished by Springer Science and Business Media LLC ,2015
- Installation, Calibration, and Application of Dielectric Sensors in Laboratory Studies of Compacted Unsaturated Granular MaterialsGeotechnical Testing Journal, 2013
- Landsliding in partially saturated materialsGeophysical Research Letters, 2009
- Theoretical analysis of the effect of temperature, cable length and double-impedance probe head on TDR water content measurementPublished by Informa UK Limited ,2008
- Field Measurement of Suction, Water Content, and Water PermeabilityGeotechnical and Geological Engineering, 2008
- Evaluation of a low-cost soil water content sensor for wireless network applicationsJournal of Hydrology, 2007
- Measurement of Soil Water Content Using a Simplified Impedance Measuring TechniqueJournal of Agricultural Engineering Research, 1996