Automated Segmentation of the Cup and Rim from Spectral Domain OCT of the Optic Nerve Head
Open Access
- 1 December 2009
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Opthalmology & Visual Science
- Vol. 50 (12), 5778-5784
- https://doi.org/10.1167/iovs.09-3790
Abstract
Purpose.: To evaluate the performance of an automated algorithm for determination of the cup and rim from close-to-isotropic spectral domain (SD) OCT images of the optic nerve head (ONH) and compare to the cup and rim as determined by glaucoma experts from stereo color photographs of the same eye. Methods.: Thirty-four consecutive patients with glaucoma were included in the study, and the ONH in the left eye was imaged with SD-OCT and stereo color photography on the same day. The cup and rim were segmented in all ONH OCT volumes by a novel voxel column classification algorithm, and linear cup-to-disc (c/d) ratio was determined. Three fellowship-trained glaucoma specialists performed planimetry on the stereo color photographs, and c/d was also determined. The primary outcome measure was the correlation between algorithm-determined c/d and planimetry-derived c/d. Results.: The correlation of algorithm c/d to experts 1, 2, and 3 was 0.90, 0.87, and 0.93, respectively. The c/d correlation of expert 1 to 2, 1 to 3, and 2 to 3, were 0.89, 0.93, and 0.88, respectively. Conclusions.: In this preliminary study, we have developed a novel algorithm to determine the cup and rim in close-to-isotropic SD-OCT images of the ONH and have shown that its performance for determination of the cup and rim from SD-OCT images is similar to that of planimetry by glaucoma experts. Validation on a larger glaucoma sample as well as normal controls is warranted.Keywords
This publication has 21 references indexed in Scilit:
- Automated 3-D Intraretinal Layer Segmentation of Macular Spectral-Domain Optical Coherence Tomography ImagesIEEE Transactions on Medical Imaging, 2009
- Automated Segmentation of the Optic Disc from Stereo Color Photographs Using Physiologically Plausible FeaturesPublished by Association for Research in Vision and Ophthalmology (ARVO) ,2007
- Effect of Glaucomatous Damage on Repeatability of Confocal Scanning Laser Ophthalmoscope, Scanning Laser Polarimetry, and Optical Coherence TomographyPublished by Association for Research in Vision and Ophthalmology (ARVO) ,2007
- Segmentation of the Surfaces of the Retinal Layer from OCT ImagesLecture Notes in Computer Science, 2006
- Ophthalmic imaging by spectral optical coherence tomographyAmerican Journal of Ophthalmology, 2004
- Reduction of Intraocular Pressure and Glaucoma ProgressionAmerican Journal of Ophthalmology, 2002
- A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurementsBritish Journal of Ophthalmology, 2000
- Quantitative Assessment of Macular Edema With Optical Coherence TomographyAmerican Journal of Ophthalmology, 1995
- Racial variations in the prevalence of primary open-angle glaucoma. The Baltimore Eye Survey.1991
- Intraobserver and Interobserver Agreement in Measurement of Optic Disc CharacteristicsOphthalmology, 1988