Role of electrode design on the volume of tissue activated during deep brain stimulation
- 19 December 2005
- journal article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 3 (1), 1-8
- https://doi.org/10.1088/1741-2560/3/1/001
Abstract
Deep brain stimulation (DBS) is an established clinical treatment for a range of neurological disorders. Depending on the disease state of the patient, different anatomical structures such as the ventral intermediate nucleus of the thalamus (VIM), the subthalamic nucleus or the globus pallidus are targeted for stimulation. However, the same electrode design is currently used in nearly all DBS applications, even though substantial morphological and anatomical differences exist between the various target nuclei. The fundamental goal of this study was to develop a theoretical understanding of the impact of changes in the DBS electrode contact geometry on the volume of tissue activated (VTA) during stimulation. Finite element models of the electrodes and surrounding medium were coupled to cable models of myelinated axons to predict the VTA as a function of stimulation parameter settings and electrode design. Clinical DBS electrodes have cylindrical contacts 1.27 mm in diameter (d) and 1.5 mm in height (h). Our results show that changes in contact height and diameter can substantially modulate the size and shape of the VTA, even when contact surface area is preserved. Electrode designs with a low aspect ratio (d/h) maximize the VTA by providing greater spread of the stimulation parallel to the electrode shaft without sacrificing lateral spread. The results of this study provide the foundation necessary to customize electrode design and VTA shape for specific anatomical targets, and an example is presented for the VIM. A range of opportunities exist to engineer DBS systems to maximize stimulation of the target area while minimizing stimulation of non-target areas. Therefore, it may be possible to improve therapeutic benefit and minimize side effects from DBS with the design of target-specific electrodes.Keywords
This publication has 31 references indexed in Scilit:
- Sources and effects of electrode impedance during deep brain stimulationClinical Neurophysiology, 2005
- Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulationClinical Neurophysiology, 2005
- Bilateral Deep-Brain Stimulation of the Globus Pallidus in Primary Generalized DystoniaNew England Journal of Medicine, 2005
- Cellular Effects of Deep Brain Stimulation: Model-Based Analysis of Activation and InhibitionJournal of Neurophysiology, 2004
- Histological analysis of the location of effective thalamic stimulation for tremorJournal of Neurosurgery, 2004
- Electric field and stimulating influence generated by deep brain stimulation of the subthalamic nucleusClinical Neurophysiology, 2004
- Prediction of Myelinated Nerve Fiber Stimulation Thresholds: Limitations of Linear ModelsIEEE Transactions on Biomedical Engineering, 2004
- Postoperative management of Vim DBS for tremorMovement Disorders, 2002
- Introduction to the programming of deep brain stimulatorsMovement Disorders, 2002
- Analysis of a linear model for electrical stimulation of axons-critical remarks on the "activating function concept"IEEE Transactions on Biomedical Engineering, 2001