Abstract
Control structures and strategies have a critical influence on a power electronic converter's behavior during disturbances. Most of the previous works in the field of pulsewidth modulation voltage-source converter (VSC) operation under unbalanced conditions propose dual vector controllers with dc bus voltage optimization strategies, which have been proven to be well adapted for rectifier applications. In this paper, two major contributions are made. On the one hand, a new optimized operation strategy based on exchanged power maximization is proposed for vector control structures, which permits the extension of optimized operation to other VSC applications (e.g., flexible alternating current transmission system and distributed generation interfaces). On the other hand, a scalar control structure is proposed based on resonant controllers, together with three adapted optimized operation strategies, namely: 1) dc bus voltage optimization; 2) power exchange maximization; and 3) a hybrid strategy (an intermediary mode between the other two strategies). Their main advantage is their simplicity and the lack of real-time symmetrical component extraction techniques. This scalar controller and the proposed optimized operation strategies are compared to conventional vector controllers. It is proven through experimental analysis that the proposed scalar controller offers very good performances with simpler structures and bigger flexibility in terms of operation modes.Keywords
This publication has 17 references indexed in Scilit:
- Decoupled Double Synchronous Reference Frame PLL for Power Converters ControlIEEE Transactions on Power Electronics, 2007
- Overview of Control and Grid Synchronization for Distributed Power Generation SystemsIEEE Transactions on Industrial Electronics, 2006
- A new single-phase PLL structure based on second order generalized integratorPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2006
- Voltage Tolerance Testing of Three-Phase Voltage Source ConvertersIEEE Transactions on Power Delivery, 2005
- Transient performance of voltage source converter under unbalanced voltage dipsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2004
- Performance evaluation of PLL algorithms for single-phase grid-connected systemsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2004
- A Method for Synchronization of Power Electronic Converters in Polluted and Variable-Frequency EnvironmentsIEEE Transactions on Power Systems, 2004
- Stationary frame current regulation of PWM inverters with zero steady-state errorIEEE Transactions on Power Electronics, 2003
- Transient operation of grid-connected voltage source converter under unbalanced voltage conditionsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Phase-locked loop techniques. A surveyIEEE Transactions on Industrial Electronics, 1996