A five-station hip joint simulator
- 1 January 2001
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 215 (1), 61-64
- https://doi.org/10.1243/0954411011533535
Abstract
A five-station hip joint wear simulator was designed and built which featured simplified motion and loading. An elliptical wear path was produced using approximately sinusoidal motion in the flexion/extension and internal/external rotation axes and the dynamic loading approximated to a square wave. Five 28 mm diameter zirconia femoral heads articulated against ultra-high molecular weight polyethylene acetabular cups in 25 per cent bovine serum for 5 × 106 cycles. Gravimetric wear measurement was used with moisture absorption compensation using a dynamically loaded soak control. With motion of physiological magnitude, the mean acetabular cup wear rate was 52.2 mm3/106 cycles which is comparable with a number of clinical studies.Keywords
This publication has 9 references indexed in Scilit:
- Simplified motion and loading compared to physiological motion and loading in a hip joint simulatorProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000
- A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and ratesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999
- A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulatorProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999
- The Importance of Multidirectional Motion on the Wear of PolyethyleneProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996
- Polyethylene wear in cemented metal-backed acetabular cupsThe Journal of Bone and Joint Surgery. British volume, 1993
- In vivo wear of polyethylene acetabular componentsThe Journal of Bone and Joint Surgery. British volume, 1993
- Long-term results of staple capsulorrhaphy for anterior instability of the shoulder.The Journal of Bone & Joint Surgery, 1993
- Design and Development of a Versatile Hip Joint Simulator and a Preliminary Assessment of Wear and Creep in Charnley Total Replacement Hip JointsEngineering in Medicine, 1988
- Measurement of Hip-Joint Motion during WalkingThe Journal of Bone & Joint Surgery, 1969