A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT—helical scanning
- 25 January 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (4), 855-874
- https://doi.org/10.1088/0031-9155/51/4/007
Abstract
Based on the structure of the original helical FDK algorithm, a three-dimensional (3D)-weighted cone beam filtered backprojection (CB-FBP) algorithm is proposed for image reconstruction in volumetric CT under helical source trajectory. In addition to its dependence on view and fan angles, the 3D weighting utilizes the cone angle dependency of a ray to improve reconstruction accuracy. The 3D weighting is ray-dependent and the underlying mechanism is to give a favourable weight to the ray with the smaller cone angle out of a pair of conjugate rays but an unfavourable weight to the ray with the larger cone angle out of the conjugate ray pair. The proposed 3D-weighted helical CB-FBP reconstruction algorithm is implemented in the cone-parallel geometry that can improve noise uniformity and image generation speed significantly. Under the cone-parallel geometry, the filtering is naturally carried out along the tangential direction of the helical source trajectory. By exploring the 3D weighting's dependence on cone angle, the proposed helical 3D-weighted CB-FBP reconstruction algorithm can provide significantly improved reconstruction accuracy at moderate cone angle and high helical pitches. The 3D-weighted CB-FBP algorithm is experimentally evaluated by computer-simulated phantoms and phantoms scanned by a diagnostic volumetric CT system with a detector dimension of 64 x 0.625 mm over various helical pitches. The computer simulation study shows that the 3D weighting enables the proposed algorithm to reach reconstruction accuracy comparable to that of exact CB reconstruction algorithms, such as the Katsevich algorithm, under a moderate cone angle (4 degrees) and various helical pitches. Meanwhile, the experimental evaluation using the phantoms scanned by a volumetric CT system shows that the spatial resolution along the z-direction and noise characteristics of the proposed 3D-weighted helical CB-FBP reconstruction algorithm are maintained very well in comparison to the FDK-type algorithms. Moreover, the experimental evaluation by clinical data verifies that the proposed 3D-weighted CB-FBP algorithm for image reconstruction in volumetric CT under helical source trajectory meets the challenges posed by diagnostic applications of volumetric CT imaging.This publication has 37 references indexed in Scilit:
- An approximate short scan helical FDK cone beam algorithm based on nutating curved surfaces satisfying the Tuy's conditionMedical Physics, 2005
- Extended parallel backprojection for standard three‐dimensional and phase‐correlated four‐dimensional axial and spiral cone‐beam CT with arbitrary pitch, arbitrary cone‐angle, and 100% dose usageMedical Physics, 2004
- Advanced single‐slice rebinning in cone‐beam spiral CTMedical Physics, 2000
- A solution to the long-object problem in helical cone-beam tomographyPhysics in Medicine & Biology, 2000
- Multi‐slice helical CT: Scan and reconstructionMedical Physics, 1999
- Exact regional reconstruction of longitudinally unbounded objects using the circle-and-line cone-beam tomographic systemPublished by SPIE-Intl Soc Optical Eng ,1997
- A general approach to the reconstruction of x-ray helical computed tomographyMedical Physics, 1996
- A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojectionIEEE Transactions on Medical Imaging, 1994
- Computed tomography scanning with simultaneous patient translationMedical Physics, 1990
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984