Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS) technique
Open Access
- 17 April 2013
- journal article
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 6 (4), 1031-1040
- https://doi.org/10.5194/amt-6-1031-2013
Abstract
Accurate measurements of carbon monoxide (CO) in humid air have been made using the cavity ring-down spectroscopy (CRDS) technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near-infrared region (~1.57 μm) after removing interferences from adjacent carbon dioxide (CO2) and water vapor (H2O) absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360–390 ppm and for reported H2O mole fractions between 0–4%. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately −0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of −0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs improved spectroscopic model functions for CO2, H2O, and CO to fit the raw spectral data (available since the beginning of 2012) indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.Keywords
This publication has 23 references indexed in Scilit:
- Long-term greenhouse gas measurements from aircraftAtmospheric Chemistry and Physics, 2013
- Effect of air composition (N2, O2, Ar, and H2O) on CO2 and CH4 measurement by wavelength-scanned cavity ring-down spectroscopy: calibration and measurement strategyAtmospheric Chemistry and Physics, 2012
- A Fourier transform infrared trace gas and isotope analyser for atmospheric applicationsAtmospheric Chemistry and Physics, 2012
- Validation of routine continuous airborne CO2 observations near the Bialystok Tall TowerAtmospheric Chemistry and Physics, 2012
- High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4) using the cavity ring-down spectroscopy (CRDS) techniqueAtmospheric Chemistry and Physics, 2009
- The tropospheric cycle of H2: a critical reviewTellus B: Chemical and Physical Meteorology, 2009
- Reanalysis of tropospheric CO trends: Effects of the 1997–1998 wildfiresJournal of Geophysical Research: Atmospheres, 2003
- Emission of trace gases and aerosols from biomass burningGlobal Biogeochemical Cycles, 2001
- Integrated cavity output analysis of ultra-weak absorptionChemical Physics Letters, 1998
- Tropospheric chemistry: A global perspectiveJournal of Geophysical Research: Oceans, 1981