Variability of measured resting metabolic rate
Open Access
- 1 December 2003
- journal article
- research article
- Published by Elsevier BV in The American Journal of Clinical Nutrition
- Vol. 78 (6), 1141-1144
- https://doi.org/10.1093/ajcn/78.6.1141
Abstract
Background: The necessity of a 12-h fast before resting metabolic rate (RMR) is measured is often a barrier to measuring RMR. Objective: We compared RMR measurements obtained in the morning and afternoon and across repeated days to elucidate the magnitude and sources of variability. Design: Healthy men (n = 12) and women (n = 25) aged 21–67 y, with body mass indexes (in kg/m2) ranging from 17 to 34 and body fat ranging from 6% to 54%, completed 4 RMR measurements. RMR measurements were made in the morning (after a 12-h fast and 12 h postexercise) and in the afternoon (after a 4-h fast and 12 h postexercise) on 2 separate days with the ventilated-hood technique. Body composition was assessed by dual-energy X-ray absorptiometry. Results: Mean (± SE) afternoon RMR was significantly higher than morning RMR on both visit 1 (1593.5 ± 35.6 compared with 1508.0 ± 31.5 kcal/d; P = 0.001) and visit 2 (1602 ± 29.3 compared with 1511.4 ± 35.9 kcal/d; P = 0.001). The 2 morning measurements (r = 0.93) and the 2 afternoon measurements (r = 0.93) were highly correlated, and no significant differences between measurements were observed. The mean difference between the morning and afternoon measurements was 99.0 ± 35.8 kcal/d (6%). Conclusions: Repeated morning and evening measurements of RMR were stable and highly correlated. Day-to-day measurements of RMR were not significantly different. RMR measured in the afternoon after a 4-h fast and exercise was ≈100 kcal/d higher than RMR measured in the morning.This publication has 17 references indexed in Scilit:
- A new handheld device for measuring resting metabolic rate and oxygen consumptionJournal of the American Dietetic Association, 2003
- Estimating energy expenditure from the Minnesota Leisure Time Physical Activity and Tecumseh Occupational Activity questionnaires – a doubly labeled water validationJournal of Clinical Epidemiology, 2002
- Within- and between-subject variation in energy expenditure measured by the doubly-labelled water technique: implications for validating reported dietary energy intakeEuropean Journal of Clinical Nutrition, 2000
- Validation of Aerosport KB1-C Portable Metabolic SystemInternational Journal of Sports Medicine, 1999
- Acute effect of ephedrine on 24-h energy balanceClinical Science, 1999
- Reproducibility of resting metabolic rate measurement in childrenBritish Journal of Nutrition, 1999
- Clinical validation of the Deltatrac monitoring system in mechanically ventilated patientsIntensive Care Medicine, 1995
- A Validation and Comparison Study of Two Metabolic MonitorsJournal of Parenteral and Enteral Nutrition, 1990
- Reproducibility of 24 h energy expenditure measurements using a human whole body indirect calorimeterBritish Journal of Nutrition, 1987
- New methods for calculating metabolic rate with special reference to protein metabolismJournal Of Physiology-London, 1949