Standard splenic volume in children and young adults measured from CT images
- 1 August 1997
- journal article
- Published by Springer Science and Business Media LLC in Surgery Today
- Vol. 27 (8), 726-728
- https://doi.org/10.1007/bf02384985
Abstract
The number of children and adolescents with hypersplenism is increasing as the number of long-term survivors undergoing successful Kasai operation for biliary atresia increases. The aim of this study was to determine the standard splenic volume in normal children and adolescents. We measured the splenic volumes with computed tomography (CT) images obtained from 49 Japanese children, adolescents, and young adults, ranging from 9 days to 25 years of age, and from 3.0 kg to 89.0 kg of body weight. The best correlation was observed between splenic volume (SV: cm3) and body weight (BW: kg) with a power curve regression; SV=6.516 BW0.797,r=0.924. The splenic volume and age (AG: years) also correlated well on a power curve; SV=41.879 AG0.411,r=0.897. The ratio of the splenic volume to the body weight (SV/BW: cm3/kg) decreased with age; from 4.5 cm3/kg at 1 month to 2.4 cm3/kg at 25 years of age, according to an exponential curve; SV/BW=4.473e−0.026AG,r=0.593. The above formulas are thus considered to be clinically useful, especially in the assessment of splenic size in children with hypersplenism both before and after partial splenic embolization.Keywords
This publication has 14 references indexed in Scilit:
- Changes in splenic volume after partial splenic embolization in childrenJournal of Pediatric Surgery, 1996
- Calculation of child and adult standard liver volume for liver transplantationHepatology, 1995
- Calculation of child and adult standard liver volume for liver transplantationHepatology, 1995
- CT Assessment of Normal Splenic Size in ChildrenActa Radiologica, 1994
- Volume of the spleen in children as measured on CT scans: normal standards as a function of body weight.American Journal of Roentgenology, 1993
- Automated Volume Determination of the Liver and Spleen from Tc-99m Colloid SPECT Imaging Quantification of the Liver Functional and Nonfunctional Tissue in DiseaseClinical Nuclear Medicine, 1990
- Optimum processing protocols for volume determination of the liver and spleen from SPECT imaging with technetium-99m sulfur colloid.1988
- Volume determinations using computed tomographyAmerican Journal of Roentgenology, 1982
- Correlation between sectional area of the spleen by ultrasonic tomography and actual volume of the removed spleenJournal of Clinical Ultrasound, 1979
- Accurate Measurement of Liver, Kidney, and Spleen Volume and Mass by Computerized Axial TomographyAnnals of Internal Medicine, 1979