Echocardiographic Variables After Left Ventricular Assist Device Implantation Associated With Adverse Outcome
- 1 November 2011
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Circulation: Cardiovascular Imaging
- Vol. 4 (6), 648-661
- https://doi.org/10.1161/circimaging.111.965335
Abstract
Background—: Operative mortality after left ventricular assist device (LVAD) implantation is heavily influenced by patient selection and the technical difficulty of surgery. However, how we treat our patients and LVAD setting may affect the patient outcome beyond this period. We postulated that the presence of echocardiographic variables 1 month after surgery suggesting appropriate degree of LV unloading and an adequate forward flow would be important in determining clinical outcomes after the initial successful LVAD implantation. Methods and Results—: We retrospectively analyzed various variables in echocardiographic examinations performed 30 days after LVAD implant in 76 consecutive patients receiving continuous flow device for their association with a compound end point (90-day mortality, readmission for heart failure, or New York Heart Association class III or higher at the end of the 90-day period). The echocardiographic associations examined included estimated LVAD flow, with and without native LV contribution, interventricular septal position, the status of aortic valve opening, an estimated left atrial pressure (ELAP), the mitral flow E-wave deceleration time, and the ratio of deceleration time to E-wave velocity (mitral deceleration index [MDI]). Four patients died during the 30- to 90-day period, 6 patients were readmitted for heart failure, and 25 patients were considered to have New York Heart Association class III or higher at the end of the 90-day period. Variables associated with adverse outcome included increased ELAP (odds ratio, 1.30 [1.16–1.48]; P P =0.02) and decreased tricuspid lateral annulus velocity (odds ratio, 0.70 implantation [0.48–0.95]; P =0.02). A leftward deviation of interventricular septum was associated with a worse outcome (odds ratio, 3.03 implantation [1.21–13.3]; P =0.01). Conclusions—: Mortality and heart failure after LVAD surgery appear to be predominantly determined by echocardiographic evidence of inefficient unloading of the left ventricle and persistence of right ventricular dysfunction. Increased estimated LA pressure and short MDI are associated with worse mid term outcome. Leftward deviation of the septum is associated with worse outcome as well.Keywords
This publication has 38 references indexed in Scilit:
- Left Ventricular Assist Device Therapy in Patients With Restrictive and Hypertrophic CardiomyopathyCirculation: Heart Failure, 2011
- Echocardiographic Predictors of Adverse Outcomes After Continuous Left Ventricular Assist Device ImplantationJACC: Cardiovascular Imaging, 2011
- Focused Review on Transthoracic Echocardiographic Assessment of Patients with Continuous Axial Left Ventricular Assist DevicesCardiology Research and Practice, 2011
- Mitral E Wave Deceleration Time to Peak E Velocity Ratio and Cardiovascular Outcome in Hypertensive Patients During Antihypertensive Treatment (from the LIFE Echo-Substudy)The American Journal of Cardiology, 2009
- Use of a Continuous-Flow Device in Patients Awaiting Heart TransplantationNew England Journal of Medicine, 2007
- Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cavaThe American Journal of Cardiology, 1990
- Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findingsThe American Journal of Cardiology, 1986
- Evaluation of size and dynamics of the inferior vena cava as an index of right-sided cardiac functionThe American Journal of Cardiology, 1984
- A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography.Circulation, 1981
- Echocardiographic Analysis of interatrial septal motionThe American Journal of Cardiology, 1979