Background Limitations of conventional uncemented femoral stems persist, including proximal-distal mismatch, nonideal load transfer, loss of bone, and difficulties with minimally invasive surgery. Metaphyseal-engaging short-stem implants have been designed to address these issues in THA. While these devices have been studied in younger patients, it is unclear whether they offer advantages in older patients. Questions/purposes We asked whether the stability and bony ingrowth of an off-the-shelf short stem in patients 70 years and older were similar to those achieved in patients younger than 70 years at 2-year followup. Furthermore, we asked whether pain and function scores were affected by age, bone quality, or varus alignment. Patients and Methods We retrospectively reviewed 60 patients (65 hips) 70 years and older (mean, 75 years; range, 70-86 years) treated with an uncemented short stem (range, 90-105 mm). We compared radiographic alignment, stability, and bony ingrowth, as well as Harris hip scores and WOMAC pain scores, to a cohort of 89 patients (91 hips) younger than 70 years. Minimum followup was 24 months (mean, 35 months; range, 24-60 months). Results Radiographs showed proximal bony ingrowth and stable fixation of all implants. Average Harris hip score at last followup was 88 (range, 70-100) for the 70 years and older cohort and 93 (range, 70-100) for younger than 70 years cohort; no patients reported thigh pain. Postoperative WOMAC scores averaged 6 (range, 0-43) and 5 (range, 0-25), respectively. Conclusions Short-stem implants provide solid, dependable fixation in osteoporotic bone at minimum 2-year followup, while meeting some of the limitations in conventional primary THA. Level of Evidence Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 50 references indexed in Scilit:
- Modular Femoral Sleeve and Stem Implant Provides Long-term Total Hip SurvivorshipClinical Orthopaedics and Related Research, 2011
- What Works Best, a Cemented or Cementless Primary Total Hip Arthroplasty?: Minimum 17-year Followup of a Randomized Controlled TrialClinical Orthopaedics & Related Research, 2011
- THA with the ABG I Prosthesis at 15 Years: Excellent Survival with Minimal OsteolysisClinical Orthopaedics and Related Research, 2010
- Revision Total Hip Arthroplasty with a Porous-coated Modular Stem: 5 to 10 Years FollowupClinical Orthopaedics & Related Research, 2010
- Durability of Second-generation Extensively Porous-coated Stems in Patients Age 50 and YoungerClinical Orthopaedics & Related Research, 2010
- High Survival of Uncemented Proximally Porous-coated Titanium Alloy Femoral Stems in Osteoporotic BoneClinical Orthopaedics & Related Research, 2010
- Correlation of plain radiographic indices of the hip with quantitative bone mineral densityOsteoporosis International, 2007
- Hydroxyapatite-coated Femoral ComponentsClinical Orthopaedics & Related Research, 2006
- Structural and cellular assessment of bone quality of proximal femurBone, 1993