Abstract
Purpose To evaluate the accuracy of 64-section multidetector computed tomography (CT) for the assessment of perfusion defects (PDs), regional wall motion (RWM), and global left ventricular (LV) function. Materials and Methods All myocardial infarction (MI) patients signed informed consent. The IRB approved the study and it was HIPAA-compliant. Cardiac multidetector CT was performed in 102 patients (34 with recent acute MI and 68 without). Multidetector CT images were analyzed for myocardial PD, RWM abnormalities, and LV function. Global LV function and RWM were compared with transthoracic echocardiography (TTE) by using multidetector CT. PD was detected by using multidetector CT and was correlated with cardiac biomarkers and single photon emission CT (SPECT) myocardial perfusion imaging. Multidetector CT diagnosis of acute MI was made on the basis of matching the presence of PD with RWM abnormalities compared with clinical evaluation. Results Correlation between multidetector CT and TTE for global function (r = 0.68) and RWM (κ = 0.79) was good. The size of PD on multidetector CT had a moderate correlation against SPECT (r = 0.48, −7% ± 9). There was good to excellent correlation between cardiac biomarkers and the percentage infarct size by using multidetector CT (r = 0.82 for creatinine phosphokinase, r = 0.76 for creatinine phosphokinase of the muscle band, and r = 0.75 for troponin). For detection of acute MI in patients, multidetector CT sensitivity was 94% (32 of 34) and specificity was 97% (66 of 68). Multidetector CT had an excellent interobserver reliability for ejection fraction quantification (r = 0.83), as compared with TTE (r = 0.68). Conclusion Patients with acute MI can be identified by using multidetector CT on the basis of RWM abnormalities and PD. © RSNA, 2008 Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/248/2/466/DC1Keywords
This publication has 31 references indexed in Scilit:
- Differentiation of Recent and Chronic Myocardial Infarction by Cardiac Computed TomographyThe American Journal of Cardiology, 2006
- Multi–detector row cardiac computed tomography accurately quantifies right and left ventricular size and function compared with cardiac magnetic resonanceAmerican Heart Journal, 2006
- Characterization of Acute and Chronic Myocardial Infarcts by Multidetector Computed TomographyCirculation, 2006
- Contrast-Enhanced Multidetector Computed Tomography Viability Imaging After Myocardial InfarctionCirculation, 2006
- Usefulness of Multidetector Row Spiral Computed Tomography With 64- × 0.6-mm Collimation and 330-ms Rotation for the Noninvasive Detection of Significant Coronary Artery StenosesThe American Journal of Cardiology, 2005
- Assessment of Myocardial Viability in Reperfused Acute Myocardial Infarction Using 16-Slice Computed Tomography in Comparison to Magnetic Resonance ImagingJournal of the American College of Cardiology, 2005
- Assessment of Left Ventricular Parameters Using 16-MDCT and New Software for Endocardial and Epicardial Border DelineationAmerican Journal of Roentgenology, 2005
- ACC/AHA Guidelines for the Management of Patients With ST-Elevation Myocardial Infarction—Executive SummaryCirculation, 2004
- Multi-Detector Computed Tomography for Imaging of Subendocardial Infarction-Prediction of Wall Motion Recovery After Reperfused Anterior Myocardial Infarction-Circulation Journal, 2004