Scanning probe microscopes go video rate and beyond
- 26 April 2005
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 76 (5), 053710
- https://doi.org/10.1063/1.1915288
Abstract
In this article we introduce a, video-rate, control system that can be used with any type of scanning probe microscope, and that allows frame rates up to 200 images ∕ s . These electronics are capable of measuring in a fast, completely analog mode as well as in the more conventional digital mode. The latter allows measurements at low speeds and options, such as, e.g., atom manipulation, current–voltage spectroscopy, or force–distance curves. For scanning tunneling microscope (STM) application we implemented a hybrid mode between the well-known constant-height and constant-current modes. This hybrid mode not only increases the maximum speed at which the surface can be imaged, but also improves the resolution at lower speeds. Acceptable image quality at high speeds could only be obtained by pushing the performance of each individual part of the electronics to its limit: we developed a preamplifier with a bandwidth of 600 kHz , a feedback electronics with a bandwidth of 1 MHz , a home-built bus structure for the fast data transfer, fast analog to digital converters, and low-noise drivers. Future improvements and extensions to the control electronics can be realized easily and quickly, because of its open architecture with its modular plug-in units. In the second part of this article we show our high-speed results. The ultrahigh vacuum application of these control electronics on our (UHV)-STM enabled imaging speeds up to 0.3 mm ∕ s , while still obtaining atomic step resolution. At high frame rates, the images suffered from noticeable distortions, which we have been able to analyze by virtue of the unique access to the error ( d Z ) signal. The distortions have all been associated with mechanical resonances in the scan head of the UHV-STM. In order to reduce such resonance effects, we have designed and built a scan head with high resonance frequencies ( ⩾ 64 kHz ) , especially for the purpose of testing the fast electronics. Using this scanner we have reached video-rate imaging speeds up to 200 frames ∕ s ( 5 ms ∕ image ) , while still obtaining atomically resolved structures.Keywords
This publication has 22 references indexed in Scilit:
- A servomechanism for a micro-electro-mechanical-system-based scanning-probe data storage deviceNanotechnology, 2004
- Scanning tunnelling microscopy in extreme fields: very low temperature, high magnetic field, and extreme high vacuumNanotechnology, 2004
- Ultrahigh-speed scanning near-field optical microscopy capable of over 100 frames per secondApplied Physics Letters, 2003
- Grains, Growth, and GroovingPhysical Review Letters, 2003
- A high-pressure scanning tunneling microscopeReview of Scientific Instruments, 2001
- Comment on “Real Space Investigation of the Roughening and Deconstruction Transitions of Au(110)”Physical Review Letters, 2001
- The “Reactor STM”: A scanning tunneling microscope for investigation of catalytic surfaces at semi-industrial reaction conditionsReview of Scientific Instruments, 1998
- Step and kink dynamics on Au(110) and Pb(111) studied with a high-speed STMPhysical Review B, 1995
- Design and performance of a high-temperature, high-speed scanning tunneling microscopeReview of Scientific Instruments, 1995
- Surface Studies by Scanning Tunneling MicroscopyPhysical Review Letters, 1982