A High Sensitivity Preamplifier for Quartz Tuning Forks in QEPAS (Quartz Enhanced PhotoAcoustic Spectroscopy) Applications
Open Access
- 3 November 2017
- Vol. 17 (11), 2528
- https://doi.org/10.3390/s17112528
Abstract
All the preamplifiers dedicated for Quartz Enhanced PhotoAcoustic Spectroscopy (QEPAS) applications that have so far been reported in the literature have been based on operational amplifiers working in transimpedance configurations. Taking into consideration that QEPAS sensors are based on quartz tuning forks, and that quartz has a relatively high voltage constant and relatively low charge constant, it seems that a transimpedance amplifier is not an optimal solution. This paper describes the design of a quartz QEPAS sensor preamplifier, implemented with voltage amplifier configuration. Discussion of an electrical model of the circuit and preliminary measurements are presented. Both theoretical analysis and experiments show that use of the voltage configuration allows for a substantial increase of the output signal in comparison to the transimpedance circuit with the same tuning fork working in identical conditions. Assuming that the sensitivity of the QEPAS technique depends directly on the properties of the preamplifier, use of the voltage amplifier configuration should result in an increase of QEPAS sensitivity by one to two orders of magnitude.Keywords
This publication has 16 references indexed in Scilit:
- Analog Front-End Circuitry in Piezoelectric and Microphone Detection of Photoacoustic SignalsInternational Journal of Thermophysics, 2014
- Sensitivity Comparison of Vapor Trace Detection of Explosives Based on Chemo-Mechanical Sensing with Optical Detection and Capacitive Sensing with Electronic DetectionSensors, 2014
- Quartz-Enhanced Photoacoustic Spectroscopy: A ReviewSensors, 2014
- QEPAS for chemical analysis of multi-component gas mixturesApplied Physics B Laser and Optics, 2010
- Photoacoustic Techniques for Trace Gas Sensing Based on Semiconductor Laser SourcesSensors, 2009
- Introduction to the quartz tuning forkAmerican Journal of Physics, 2007
- Applications of quartz tuning forks in spectroscopic gas sensingReview of Scientific Instruments, 2005
- Trace gas monitoring by laser photoacoustic spectroscopy and related techniques (plenary)Review of Scientific Instruments, 2003
- LASER PHOTOACOUSTIC TRACE GAS DETECTION, AN EXTREMELY SENSITIVE TECHNIQUE APPLIED IN BIOLOGICAL RESEARCHInstrumentation Science & Technology, 1998
- Tunable diode laser monitoring of atmospheric trace gas constituentsSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 1995