Abstract
Small-signal stability in balanced three-phase systems can be analyzed using Generalized Nyquist stability Criterion (GNC), which is based on source and load impedances in synchronous rotating (d-q) frame. The derivation of d-q input impedance of controlled power electronics converters is relatively easy in the case that current controller is implemented in d-q reference frame, while the analysis in the case of stationary (α-β) reference frame controller is missing. This paper addresses such analysis for Active Front End (AFE) rectifier with different α-β frame linear current regulators, with a focus on the resonant controllers, and Phase-Locked Loop (PLL). A comparison in terms of input impedance of stationary and rotating frame current controller is also reported. Simulation and experimental results verify the validity of the proposed analysis.

This publication has 10 references indexed in Scilit: