Wrong biochemistry results
- 29 September 2001
- Vol. 323 (7315), 705-706
- https://doi.org/10.1136/bmj.323.7315.705
Abstract
References 1.↵ Berson SA, Yalow R, Bauman MA, Newerly K .I131 insulin metabolism in human subjects: demonstration of insulin binding globulin in the circulation of insulin-treated subjects.J Clin Invest1956;35:170–190. 2.↵ Kricka LJ .Interference in immunoassays—still a threat.Clin Chem2000;46:1037–1038. 3.↵ Selby C .Interference in immunoassays.Ann Clin Biochem1999;36:704–721. 4.↵ Ward G, McKinnon, Badrick T, Hickman PE .Heterophilic antibodies remain a problem for the immunoassay laboratory.Am J Clin Pathol1997;108:417–421. 5.↵ Cole LA, Rinne KM, Shahabi S, Omrani A .False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma.Clin Chem1999;45:313–314. 6.↵ Rotmensch S, Cole LA .False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotrophin concentrations.Lancet2000;355:712–715. 7.↵ Torjesen PA, Bjøro T .Antibodies against I125 testosterone in patient's serum: A problem for the laboratory and the patient.Clin Chem1996;43: 2047–2048. [the correct citation is Clin Chem 1996; 42:2047–2048] 8.↵ Cavinsky M, Laterza O, Pfeifer JD, Farkas ST, Scott MG .IgM antibody to Escherichia coli produces false positive results in multiple immunometric assays.Clin Chem2000;46:1157–1161. 9.↵ Krahn J, Parry DM, Laroux M, Dalton J .High percentage of false positive cardiac troponin I results in patients with rheumatoid factor.Clin Biochem1999;32:477–480. 10.↵ Bohner J, von Pape KW, Hannes W, Stegmann T .False-negative immunoassay results for cardiac troponin I probably due to circulating troponin I autoantibodies.Clin Chem1996;42:2046–2047. 11.↵ Norden AGW, Jackson RA, Norden LE, Griffin AJ, Barnes MA, Little JA .Misleading results for immunoassays of serum free thyroxine in the presence of rheumatoid factor.Clin Chem1997;43:957–962. 12.↵ Kuroki M, Matsumoto Y, Arakawa F, Haruno M, Murakami M, Kuwahara M, et al .Reducing interference from heterophilic antibodies in a two-site immunoassay for carcinoembryonic antigen (CEA) by using human-mouse chimeric antibody to CEA as the tracer.J Immunol Methods1995;180:81–91. 13.↵ Weber TH, Kapyaho KI, Tanner P .Endogenous interference in immunoassays in clinical chemistry. A review.Scan J Clin Lab Invest1990;50(suppl 201):77–82.This publication has 13 references indexed in Scilit:
- Interferences in immunoassay--still a threat.2000
- An IgM lambda antibody to Escherichia coli produces false-positive results in multiple immunometric assays.2000
- False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrationsThe Lancet, 2000
- Interference in ImmunoassayAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1999
- High percentage of false positive cardiac troponin I results in patients with rheumatoid factorClinical Biochemistry, 1999
- False-Positive hCG Assay Results Leading to Unnecessary Surgery and Chemotherapy and Needless Occurrences of Diabetes and ComaClinical Chemistry, 1999
- Heterophilic Antibodies Remain a Problem for the Immunoassay LaboratoryAmerican Journal of Clinical Pathology, 1997
- Misleading results from immunoassays of serum free thyroxine in the presence of rheumatoid factorClinical Chemistry, 1997
- Reducing interference from heterophilic antibodies in a two-site immunoassay for carcinoembryonic antigen (CEA) by using a human/mouse chimeric antibody to CEA as the tracerJournal of Immunological Methods, 1995
- INSULIN-I131 METABOLISM IN HUMAN SUBJECTS: DEMONSTRATION OF INSULIN BINDING GLOBULIN IN THE CIRCULATION OF INSULIN TREATED SUBJECTS 1JCI Insight, 1956