Measurement of radiation dose in dental radiology
- 17 May 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 114 (1-3), 168-171
- https://doi.org/10.1093/rpd/nch502
Abstract
Patient dose audit is an important tool for quality control and it is important to have a well-defined and easy to use method for dose measurements. In dental radiology, the most commonly used dose parameters for the setting of diagnostic reference levels (DRLs) are the entrance surface air kerma (ESAK) for intraoral examinations and dose width product (DWP) for panoramic examinations. DWP is the air kerma at the front side of the secondary collimator integrated over the collimator width and an exposure cycle. ESAK or DWP is usually measured in the absence of the patient but with the same settings of tube voltage (kV), tube current (mA) and exposure time as with the patient present. Neither of these methods is easy to use, and, in addition, DWP is not a risk related quantity. A better method of monitoring patient dose would be to use a dose area product (DAP) meter for all types of dental examinations. In this study, measurements with a DAP meter are reported for intraoral and panoramic examinations. The DWP is also measured with a pencil ionisation chamber and the product of DWP and the height H (DWP × H) of the secondary collimator (measured using film) was compared to DAP. The results show that it is feasible to measure DAP using a DAP meter for both intraoral and panoramic examinations. The DAP is therefore recommended for the setting of DRLs.Keywords
This publication has 7 references indexed in Scilit:
- Measurement of dose–width product in panoramic dental radiologyThe British Journal of Radiology, 2003
- Measurement of dose in panoramic dental radiology.The British Journal of Radiology, 2000
- Sensitivity of coefficients for converting entrance surface dose and kerma-area product to effective dose and energy imparted to the patientPhysics in Medicine & Biology, 1999
- Reference doses for dental radiographyBritish Dental Journal, 1999
- Ionization chambers for measuring air kerma integrated over beam area. Deviations in calibration values using simplified calibration methodsPhysics in Medicine & Biology, 1998
- 1992 assessment of radiation risk from dental radiography.Dento maxillo facial radiology, 1992
- Energy imparted to the patient in diagnostic radiology: calculation of conversion factors for determining the energy imparted from measurements of the air collision kerma integrated over beam areaPhysics in Medicine & Biology, 1984