Abstract
The term “calibration” in accelerometry research has come to mean the conversion of counts into other established measurement units. In this article, two types of calibration research are described. Unit calibration (or interinstrument variability) is described as a reliability issue, whereas value calibration is described as more of a validity issue. Principles for design of accelerometry-based validation studies are described to provide a guide for future calibration research. The population must be representative of the intended population in terms of demographics and size, monitors must be representative of the population of monitors that would be available, and activities in the protocol must be representative of the types of activities performed by the intended population. It is also important to employ appropriate analytical strategies in this type of research. A case study employing the appropriate design principles is included to demonstrate how results can vary depending on the type of analyses that are used. Direct comparisons are made between a mixed model regression approach and an approach based on receiver operator characteristic curves.Keywords
This publication has 41 references indexed in Scilit:
- Body movement and physical activity energy expenditure in children and adolescents: how to adjust for differences in body size and ageThe American Journal of Clinical Nutrition, 2004
- Validity of uniaxial accelerometry during activities of daily living in childrenEuropean Journal of Applied Physiology, 2004
- Influence of Step Frequency on Movement Intensity Predictions with the CSA Accelerometer: A Field Validation Study in ChildrenPediatric Exercise Science, 2003
- Reexamination of Validity and Reliability of the CSA Monitor in Walking and RunningMedicine & Science in Sports & Exercise, 2003
- Reliability and Validity of the Computer Science and Applications Accelerometer in a Mechanical SettingMeasurement in Physical Education and Exercise Science, 2003
- Field evaluation of energy expenditure in women using Tritrac accelerometersMedicine & Science in Sports & Exercise, 2002
- Physical activity assessed by activity monitor and doubly labeled water in childrenMedicine & Science in Sports & Exercise, 2001
- Validity of four motion sensors in measuring moderate intensity physical activityMedicine & Science in Sports & Exercise, 2000
- Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walkingMedical & Biological Engineering & Computing, 1997
- Calorimetric Validation of the Caltrac® Accelerometer During Level WalkingPTJ: Physical Therapy & Rehabilitation Journal, 1989