MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence
Top Cited Papers
Open Access
- 13 April 2012
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 53 (5), 796-804
- https://doi.org/10.2967/jnumed.111.092577
Abstract
Accurate γ-photon attenuation correction (AC) is essential for quantitative PET/MRI as there is no simple relation between MR image intensity and attenuation coefficients. Attenuation maps (μ-maps) can be derived by segmenting MR images and assigning attenuation coefficients to the compartments. Ultrashort-echo-time (UTE) sequences have been used to separate cortical bone and air, and the Dixon technique has enabled differentiation between soft and adipose tissues. Unfortunately, sequential application of these sequences is time-consuming and complicates image registration. Methods: A UTE triple-echo (UTILE) MRI sequence is proposed, combining UTE sampling for bone detection and gradient echoes for Dixon water–fat separation in a radial 3-dimensional acquisition (repetition time, 4.1 ms; echo times, 0.09/1.09/2.09 ms; field strength, 3 T). Air masks are derived mainly from the phase information of the first echo; cortical bone is segmented using a dual-echo technique. Soft-tissue and adipose-tissue decomposition is achieved using a 3-point Dixon-like decomposition. Predefined linear attenuation coefficients are assigned to classified voxels to generate MRI-based μ-maps. The results of 6 patients are obtained by comparing μ-maps, reciprocal sensitivity maps, reconstructed PET images, and brain region PET activities based on either CT AC, two 3-class MRI AC techniques, or the proposed 4-class UTILE AC. Results: Using the UTILE MRI sequence, an acquisition time of 214 s was achieved for the head-and-neck region with 1.75-mm isotropic resolution, compared with 164 s for a single-echo UTE scan. MRI-based reciprocal sensitivity maps show a high correlation with those derived from CT scans (R2 = 0.9920). The same is true for PET activities (R2 = 0.9958). An overall voxel classification accuracy (compared with CT) of 81.1% was reached. Bone segmentation is inaccurate in complex regions such as the paranasal sinuses, but brain region activities in 48 regions across 6 patients show a high correlation after MRI-based and CT-based correction (R2 = 0.9956), with a regression line slope of 0.960. All overall correlations are higher and brain region PET activities more accurate in terms of mean and maximum deviations for the 4-class technique than for 3-class techniques. Conclusion: The UTILE MRI sequence enables the generation of MRI-based 4-class μ-maps without anatomic priors, yielding results more similar to CT-based results than can be obtained with 3-class segmentation only.Keywords
This publication has 17 references indexed in Scilit:
- MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time SequencesJournal of Nuclear Medicine, 2010
- Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT DataJournal of Nuclear Medicine, 2009
- MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas RegistrationJournal of Nuclear Medicine, 2008
- Simultaneous MR/PET Imaging of the Human Brain: Feasibility StudyRadiology, 2008
- Simultaneous PET-MRI: a new approach for functional and morphological imagingNature Medicine, 2008
- Selective 3D ultrashort TE imaging: comparison of “dual-echo” acquisition and magnetization preparation for improving short-T 2 contrastMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- Water–fat separation with IDEAL gradient‐echo imagingJournal of Magnetic Resonance Imaging, 2007
- Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted samplingMagnetic Resonance in Medicine, 2006
- Multicoil Dixon chemical species separation with an iterative least‐squares estimation methodMagnetic Resonance in Medicine, 2003
- Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correctionMagnetic Resonance in Medicine, 1991