Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material
- 1 February 2012
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Investigative Radiology
- Vol. 47 (2), 142-147
- https://doi.org/10.1097/rli.0b013e31823076a4
Abstract
To investigate the feasibility of an 80-kVp protocol using a moderate concentration contrast material (MC-CM) for cerebral computed tomography angiography by comparison with a conventional 120-kVp protocol using a high concentration contrast material (HC-CM). Attenuation values and signal-to-noise ratios (SNRs) were determined in a head phantom for 2 tube voltages (80 and 120 kVp) and 2 different iodine concentration contrast materials (HC-CM and MC-CM). Among 90 consecutive patients, 45 patients were scanned with 120 kVp and 150 mAs(eff) after administration of 70 mL of HC-CM (370 mg iodine [mgI]/mL), whereas the other 45 patients were scanned with 80 kVp and 370 mAs(eff) after administration of 70 mL of MC-CM (300 mgI/mL). The Hounsfield units (HU) of the internal carotid artery T junction, SNR, contrast-to-noise ratio (CNR), subjective degree of arterial enhancement, image noise, sharpness of the cerebral arterial boundary, and overall diagnostic image quality were compared between the 2 groups. The mean attenuation of the internal carotid artery T junction, SNR, and CNR was significantly higher in the 80 kVp with MC-CM group (379.2, 33.7, and 31.1 HU, respectively) than in the 120 kVp with HC-CM group (282.2, 31.1, and 27.2 HU, respectively). The 80-kVp protocol resulted in significantly higher score in arterial enhancement, sharpness of the cerebral arteries, and overall diagnostic image quality. The effective dose of 80 kVp (0.7 mSv) was 22.2% lower than that of 120 kVp (0.9 mSv). The use of 80 kVp with MC-CM improved arterial enhancement, SNR, and CNR and provided superior quality images using a smaller amount of iodine and a lower radiation dose than the conventional protocol of 120 kVp with HC-CM.Keywords
This publication has 30 references indexed in Scilit:
- Viscosity of Contrast Media Perturbs Renal HemodynamicsJournal of the American Society of Nephrology, 2007
- Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomographyRadiation Medicine, 2006
- Renal failure in 57925 patients undergoing coronary procedures using iso-osmolar or low-osmolar contrast mediaKidney International, 2006
- New Techniques in CT AngiographyRadioGraphics, 2006
- Pathophysiology of Contrast-Induced NephropathyThe American Journal of Cardiology, 2006
- Intravenous Injection of High and Medium Concentrations of Computed Tomography Contrast Media and Related Heat Sensation, Local Pain, and Adverse ReactionsJournal of Computer Assisted Tomography, 2005
- Pathophysiology of contrast medium–induced nephropathyKidney International, 2005
- Use of guiding sheaths in peroral fluoroscopic gastroduodenal stent placementEuropean Radiology, 2005
- Nephrotoxic Effects in High-Risk Patients Undergoing AngiographyThe New England Journal of Medicine, 2003
- Pathophysiology of Radiocontrast NephropathyInvestigative Radiology, 1999