Evaluation of Passive Samplers for Assessment of Community Exposure to Toxic Air Contaminants and Related Pollutants
- 15 February 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 45 (6), 2243-2249
- https://doi.org/10.1021/es102500v
Abstract
The precision, accuracy, and sampling rates of Radiello and Ogawa passive samplers were evaluated in the laboratory using a flow-through chamber and under field conditions prior to their use in the 2007 Harbor Community Monitoring Study (HCMS), a saturation monitoring campaign in the communities adjacent to the Ports of Los Angeles and Long Beach. Passive methods included Radiello samplers for volatile organic compounds (benzene, toluene, ethylbenzene, xylenes, 1,3-butadiene), aldehydes (formaldehyde, acetaldehyde, acrolein) and hydrogen sulfide, and Ogawa samplers for nitrogen oxides and sulfur dioxide. Additional experiments were conducted to study the robustness of the passive sampling methods under variable ambient wind speed, sampling duration, and storage time before analysis. Our experimentally determined sampling rates were in agreement with the rates published by Radiello and Ogawa with the following exceptions: we observed a diffusion rate of 22.4 ± 0.1 mL/min for benzene and 37.4 ± 1.5 mL/min for ethylbenzene compared to the Radiello published values of 27.8 and 25.7 mL/min, respectively. With few exceptions, the passive monitoring methods measured one-week average ambient concentrations of selected pollutants with sensitivity and precision comparable to conventional monitoring methods averaged over the same period. Radiello Carbograph 4 VOC sampler is not suitable for the collection of 1,3-butadiene due to backdiffusion. Results for the Radiello aldehyde sampler were inconclusive due to lack of reliable reference methods for all carbonyl compounds of interest.Keywords
This publication has 14 references indexed in Scilit:
- Hydrogen sulphide as a natural air contaminant in volcanic/geothermal areas: the case of Sousaki, Corinthia (Greece)Environmental Geology, 2008
- Chapter 3 Passive sampling in combination with thermal desorption and gas chromatography as a tool for assessment of chemical exposurePublished by Elsevier BV ,2007
- Field evaluation of two diffusive samplers and two adsorbent media to determine 1,3-butadiene and benzene levels in airAtmospheric Environment, 2006
- Evaluation of two types of diffusive samplers and adsorbents for measuring 1,3-butadiene and benzene in airAtmospheric Environment, 2005
- Performances of the Radiello diffusive sampler for BTEX measurements: Influence of environmental conditions and determination of modelled sampling ratesAtmospheric Environment, 2005
- Reliability of a BTEX radial diffusive sampler for thermal desorption: field measurementsAtmospheric Environment, 2005
- Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2in El Paso, TexasJournal of the Air & Waste Management Association, 2004
- Passive measurement of nitrogen oxides to assess traffic-related pollutant exposure for the East Bay Children's Respiratory Health StudyAtmospheric Environment, 2004
- Assessment of traffic-related air pollution in two street canyons in Paris: implications for exposure studiesAtmospheric Environment, 2002
- High Uptake Rate Radial Diffusive Sampler Suitable for Both Solvent and Thermal DesorptionAihaj Journal, 1996