Proposed paper is a part of a research to develop a convenient method for continuous monitoring of blood pressure by non-invasive and non-oscillometric way. The method is based on a presumption that there is a singular relationship between the velocity of pulse wave and blood pressure for a person. The detection of the velocity of pulse wave is based on the registration of the mechanical movements of blood vessel's walls and computing the time delay in different regions of the human body using an ECG as a reference signal. Additional information about the blood pressure evaluation is gotten from the photoplethysmographic (PPG) channel. Used optical method, which is able to detect pulsation profiles of the blood vessels, is based on the self-mixing that occurs in the diode laser cavity when the radiation, scattered back by the skin into the laser, interferes with the field inside it and causes the changes of the laser pump current. National Instruments software LabView for Windows is used for output signal digitalization and processing purposes.Keywords
This publication has 12 references indexed in Scilit:
- Synchronized measurements of blood flow velocity distributions in carotid, brachial and femoral arteries, and ECG in human during exercisePublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Cuff-less ambulatory monitoring of beat-to-beat blood pressure based on a hemodynamic modelPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Estimation of systolic blood pressure variations from pulse arrival time using a narrow-band filterPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Circulatory parameter extraction from digital plethysmogram. 2. The application of parametric system identification methodsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Nonlinear analysis of pulse waves measured at brachial arteryPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Comparison of the relationship between blood pressure and pulse wave transit times at different sitesPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Simple coherence method for blood flow detectionPublished by SPIE-Intl Soc Optical Eng ,2000
- Coherent photodetection for pulse profile registrationPublished by SPIE-Intl Soc Optical Eng ,1999
- Noninvasive detection of cardiovascular pulsations by optical Doppler techniquesJournal of Biomedical Optics, 1997
- In vivo evaluation of microcirculation by coherent light scatteringNature, 1975