Liver Surface Nodularity Quantification from Routine CT Images as a Biomarker for Detection and Evaluation of Cirrhosis
- 1 September 2016
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 280 (3), 771-781
- https://doi.org/10.1148/radiol.2016151542
Abstract
To determine the accuracy, reproducibility, and intra- and interobserver agreement of a computer-based quantitative method to measure liver surface nodularity (LSN) from routine computed tomographic (CT) images as a biomarker for detection and evaluation of cirrhosis. For this institutional review board–approved HIPAA-compliant retrospective study, adult patients with healthy livers (n = 24) or various stages of hepatitis C virus–induced chronic liver disease (n = 70) with routine nonenhanced and portal venous phase contrast agent–enhanced liver CT imaging with thick-section (5.0 mm) and thin-section (1.25–1.50 mm) axial images obtained between January 1, 2006, and March 31, 2011, were identified from the electronic medical records. A computer algorithm was developed to measure LSN and derive a score. LSN scores, splenic volume, and the ratio of left lateral segment (LLS) to total liver volume (TLV) were measured from the same multiphasic liver CT examinations. Accuracy for differentiating cirrhotic from noncirrhotic livers was assessed by area under the receiver operating characteristic curve. Intra- and interobserver agreement was assessed by intraclass correlation coefficient. Median LSN scores from nonenhanced thick-section CT images in cirrhotic livers (3.16; 56 livers) were significantly higher than in noncirrhotic livers (2.11; 38 livers; P < .001). LSN scores from the four CT imaging types (94 patients for each type) were very strongly correlated (range of Spearman r, 0.929–0.960). LSN scores from portal venous phase contrast-enhanced thick-section CT images had significantly higher accuracy (area under the receiver operating characteristic curve, 0.929) than splenic volume (area under the receiver operating characteristic curve, 0.835) or LLS-to-TLV ratio measurements (area under the receiver operating characteristic curve, 0.753) for differentiating cirrhotic from noncirrhotic livers (P = .038 and .003, respectively; n = 94). Intra- and interobserver agreements that used nonenhanced thick CT images were very good (intraclass correlation coefficient, 0.963 and 0.899, respectively). Quantitative measurement of LSN on routine CT images accurately differentiated cirrhotic from noncirrhotic livers and was highly reproducible. © RSNA, 2016 Online supplemental material is available for this article.Funding Information
- Radiological Society of North America
This publication has 28 references indexed in Scilit:
- Chronic hepatitis C and liver fibrosisWorld Journal of Gastroenterology, 2014
- Evaluation for liver transplantation in adults: 2013 practice guideline by the American Association for the Study of Liver Diseases and the American Society of TransplantationJournal of Hepatology, 2013
- Screening for Hepatitis C Virus Infection in Adults: U.S. Preventive Services Task Force Recommendation StatementAnnals of Internal Medicine, 2013
- Noninvasive serum fibrosis markers for screening and staging chronic hepatitis C virus patients in a large US cohort.Clinical Infectious Diseases, 2013
- Update on the Management and Treatment of Hepatitis C Virus Infection: Recommendations from the Department of Veterans Affairs Hepatitis C Resource Center Program and the National Hepatitis C Program OfficeThe American Journal of Gastroenterology, 2012
- Noninvasive Methods to Assess Liver Disease in Patients With Hepatitis B or CGastroenterology, 2012
- Noninvasive assessment of liver fibrosisJournal of Hepatology, 2011
- Diagnosis, management, and treatment of hepatitis C: An updateJournal of Hepatology, 2008
- Liver cirrhosisThe Lancet, 2008
- Noninvasive Measures of Liver FibrosisJournal of Hepatology, 2006