Fabrication of Microfluidic Reactors and Mixing Studies for Luciferase Detection
- 2 July 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (15), 6045-6050
- https://doi.org/10.1021/ac800843v
Abstract
We report the detection of luciferase by implementing a bioluminescent assay in microfluidic reactors. The reactors were fabricated in poly(methyl methacrylate) by hot embossing using a mold master with the reactor layouts made by high-precision micromilling. The overall fabrication process was simple to implement and had a quick turnaround time with low cost. Two reactors, one with smooth channels (called reactor I) and the other with staggered herringbone mixers (called reactor II), were studied for the bioluminescent assay. The assay was implemented by introducing a sample and an assay solution into the reactors and then mixing took place to achieve the enzymatic reactions. We found that the mixing efficiency in reactor II was 17.8 times higher than reactor I. Theoretical analysis of the experimental results indicated that the required channel length of mixing was linearly proportional to the flow rate. A calibration curve for luciferase was obtained for both reactors. We found that the detection sensitivity of reactor II was 3 times higher than reactor I. The limit of detection in reactor II was determined to be 0.14 μg/mL luciferase. The device was further exploited to determine the concentration of luciferase samples obtained from in vitro protein expression.Keywords
This publication has 29 references indexed in Scilit:
- Geometrical optimization of helical flow in grooved micromixersLab on a Chip, 2007
- Cell‐Free Protein Synthesis in Microfluidic Array DevicesBiotechnology Progress, 2007
- Effects of Fabrication Process Parameters on the Properties of Cyclic Olefin Copolymer Microfluidic DevicesJournal of Microelectromechanical Systems, 2006
- Evaluation of micromilled metal mold masters for the replication of microchip electrophoresis devicesMicrofluidics and Nanofluidics, 2006
- Chip-Based Bioassay Using Bacterial Sensor Strains Immobilized in Three-Dimensional Microfluidic NetworkAnalytical Chemistry, 2004
- Deformation-Induced Release of ATP from Erythrocytes in a Poly(dimethylsiloxane)-Based Microchip with Channels That Mimic Resistance VesselsAnalytical Chemistry, 2004
- Developments toward a Microfluidic System for Long-Term Monitoring of Dynamic Cellular Events in Immobilized Human CellsAnalytical Chemistry, 2004
- Ultrasonic Mixing in Microfluidic Channels Using Integrated TransducersAnalytical Chemistry, 2004
- A barrier embedded chaotic micromixerJournal of Micromechanics and Microengineering, 2004