Biorheological Properties of Reconstructed Erythrocytes and its Function of Carrying-Releasing Oxygen
- 1 January 2009
- journal article
- Published by Taylor & Francis Ltd in Artificial Cells, Blood Substitutes, and Immobilization Biotechnology
- Vol. 37 (1), 41-44
- https://doi.org/10.1080/10731190802674477
Abstract
Erythrocyte shape and biomechanical properties have close relation to its physiological function. In this research the erythrocyte was reconstructed with natural structure protein and lipids based on cellular mechanics and hemorheology concepts. The biomechanical properties of the reconstructed erythrocyte were determined with the micropipette aspiration system. The shapes of reconstructed erythrocyte were obtained with electron scanning microscope. The oxygen carrying-releasing function was analyzed with the HEMOX analyzer from TCS, the experimental results indicated that the reconstructed erythrocytes were similar to the natural erythrocyte: having biconcave disc shape, good deformability and carrying-releasing oxygen function.Keywords
This publication has 3 references indexed in Scilit:
- Blood Substitute Resuscitation as a Treatment Modality for Moderate HypovolemiaArtificial Cells, Blood Substitutes, and Immobilization Biotechnology, 2004
- Artificial Cell Biotechnology for Medical ApplicationsBlood Purification, 2000
- Theoretical and experimental studies on viscoelastic properties of erythrocyte membraneBiophysical Journal, 1978