The antinociceptive effect of electroacupuncture at different depths of acupoints and under the needling surface
Open Access
- 27 February 2012
- journal article
- research article
- Published by Springer Science and Business Media LLC in Chinese Medicine
- Vol. 7 (1), 3
- https://doi.org/10.1186/1749-8546-7-3
Abstract
Background: The stimulation of acupoints along the meridians, but not the non-acupoints outside of the meridians, produces analgesia. Although the acupoint is defined at the body surface, the exact location of the acupoints is not known. This study aims to examine whether the intensity and duration of the analgesic effect of electroacupuncture (EA) at the Zusanli (ST36) and Sanynjiao acupoints (SP6) change according to the depth of the stimulation. Methods: Ninety-six male Wistar rats classified as responders were arbitrarily allocated into 16 groups of six rats each. Six groups received EA with uninsulated acupuncture needles (type I) or needles that were immersed in varnish and had the varnish circularly peeled 0.2 mm from the tip (type II), 0.2 mm at 3 mm (type III) or 5 mm (type IV) from the tip, or 0.2 mm at 5 and 1 mm from the tip (type V), or EA sham for 20 min. Five groups received injection of formalin into the acupoint bilaterally at 5 mm or 1 mm deep into ST36, 5 mm below ST36 but inserting the needle at 45° to the skin surface, or 5 mm deep into non-acupoints. The remaining groups received intraplantar injection of saline, 1% or 2.5% formalin. The analgesic effects were measured by the rat tail-flick test. Results: The bilateral stimulation of ST36 and SP6 by uninsulated or insulated needles produced analgesia in the rat tail-flick test. The stronger and longer lasting effects occurred after EA with the types I and V needles, or injection of formalin 5 mm deep into ST36. The remaining needles produced weaker and shorter lasting effects. Slow analgesic effect also occurred after formalin injection at 1 mm or 5 mm below ST36 by inserting the needle at 45° to the skin surface. Conclusion: The experimental results suggest that the efficacy of the EA stimulation depends on the spatial distribution of the current density under the needling surface rather than only the acupoint or the depth of needling.This publication has 47 references indexed in Scilit:
- Electroacupuncture versus celecoxib for neuropathic pain in rat SNL modelNeuroscience, 2010
- Adenosine A1 receptors mediate local anti-nociceptive effects of acupunctureNature Neuroscience, 2010
- DNIC-mediated analgesia produced by a supramaximal electrical or a high-dose formalin conditioning stimulus: roles of opioid and α2-adrenergic receptorsJournal of Biomedical Science, 2010
- Acute effect of electroacupuncture at the Zusanli acupoints on decreasing insulin resistance as shown by lowering plasma free fatty acid levels in steroid-background male ratsBMC Complementary and Alternative Medicine, 2009
- Acupuncture Muscle Channel in the Subcutaneous Layer of Rat SkinJournal of Acupuncture and Meridian Studies, 2008
- Neural mechanism underlying acupuncture analgesiaProgress in Neurobiology, 2008
- Influence of inheritance and fostering on sensitivity to effects of morphine on nociception and locomotor activity in two inbred rat strainsNeuropharmacology, 1996
- Evidence that the antinociceptive tail-flick response is produced independently from changes in either tail-skin temperature or core temperaturePain, 1993
- The role of periaqueductal gray in mediation of analgesia produced by different frequencies electroacupuncture stimulation in ratsInternational Journal of Neuroscience, 1990
- Ethical guidelines for investigations of experimental pain in conscious animalsPain, 1983