First-pass entry of nonionic contrast agent into the myocardial extravascular space. Effects on radiographic estimates of transit time and blood volume.
- 1 November 1991
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Circulation
- Vol. 84 (5), 2071-2078
- https://doi.org/10.1161/01.cir.84.5.2071
Abstract
BACKGROUND Almost all x-ray-based techniques intended to assess regional myocardial perfusion from myocardial concentration-time curves following the administration of soluble contrast agents assume that these agents behave as intravascular indicators and can therefore provide measurements of intravascular transit time and intramyocardial blood volume. METHODS AND RESULTS We tested this assumption by comparing a conventional nonionic contrast agent (ioversol) to a particulate emulsion (ethiodol) that remained in the vascular space in closed-chest dogs during pharmacological vasodilation. Using fast computed tomography (CT), pairs of myocardial CT intensity-time curves were obtained following sequential bolus aortic administration of the two contrast agents. The emulsion (particle size less than 3 microns) was almost completely washed out of the myocardial region of interest within a few seconds, as would be anticipated for a vascular indicator. At the onset of recirculation, CT intensity for ethiodol fell to 5 +/- 1% (SEM) of peak values in normally perfused areas and to 10 +/- 4% of peak values in an area in which flow had been reduced by 50% by a chronically implanted coronary artery occluder (p = NS). In comparison, the diffusible nonionic contrast agent ioversol showed substantial intramyocardial retention at the onset of recirculation. At the time of recirculation, CT intensities for ioversol averaged 36 +/- 2% of peak values in normally perfused nonstenotic areas and 54 +/- 4% of peak values in stenotic areas (p less than 0.01). Using residue function analysis for a diffusible indicator, first-pass extractions of the conventional nonionic agent averaged 33 +/- 2% in normally perfused areas and 50 +/- 3% in stenotic areas (p less than 0.01). Because of the significant first-pass myocardial retention of ioversol, both mean myocardial appearance time and intramyocardial blood volume were consistently overestimated. CONCLUSIONS Soluble radiographic contrast agents, like other small molecules, enter the interstitial space to a degree, which is important because it affects estimates of myocardial perfusion based on transit time and intramyocardial blood volume. Indicator dilution models intended to quantify myocardial perfusion with conventional radiographic contrast agents need to account for this extravascular exchange.Keywords
This publication has 9 references indexed in Scilit:
- Determination of coronary flow reserve by digital angiography: Validation of a practical method not requiring power injection or electrocardiographic gatingJournal of the American College of Cardiology, 1990
- Quantitative assesment of reductons in subendocardial and full-thickness regional flow reserve during progresssive coronary stenosis using ultrafast tomographyJournal of the American College of Cardiology, 1990
- Myocardial blood flow estimated by synchronous, multislice, high-speed computed tomographyIEEE Transactions on Medical Imaging, 1989
- Use of ultrafast computed tomography to quantitate regional myocardial perfusion: A preliminary reportJournal of the American College of Cardiology, 1987
- Tissue distribution of soluble contrast: effect of dose variation and changes with timeAmerican Journal of Roentgenology, 1981
- Formulation and Evaluation of Ethiodized Oil Emulsion for Intravenous HepatographyJournal of Pharmaceutical Sciences, 1979
- Extravascular Contrast Material: The Major Component of Contrast EnhancementRadiology, 1976
- Nitroglycerin and chromonar on small-vessel blood content of the ventricular wallsAmerican Journal of Physiology-Legacy Content, 1974
- Physiological factors influencing coronary blood volume in isolated dog heartsAmerican Journal of Physiology-Legacy Content, 1961