Flux calibration of the Herschel-SPIRE photometer
Open Access
- 5 July 2013
- journal article
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 433 (4), 3062-3078
- https://doi.org/10.1093/mnras/stt948
Abstract
We describe the procedure used to flux calibrate the three-band submillimetre photometer in the Spectral and Photometric Imaging Receiver instrument on the Herschel Space Observatory. This includes the equations describing the calibration scheme, a justification for using Neptune as the primary calibration source, a description of the observations and data processing procedures used to derive flux calibration parameters (for converting from voltage to flux density) for every bolometer in each array, an analysis of the error budget in the flux calibration for the individual bolometers and tests of the flux calibration on observations of primary and secondary calibrators. The procedure for deriving the flux calibration parameters is divided into two parts. In the first part, we use observations of astronomical sources in conjunction with the operation of the photometer internal calibration source to derive the unscaled derivatives of the flux calibration curves. To scale the calibration curves in Jy beam−1 V−1, we then use observations of Neptune in which the beam of each bolometer is mapped using a very fine scan pattern. The total instrumental uncertainties in the flux calibration for most individual bolometers is ∼0.5 per cent, although a few bolometers have uncertainties of ∼1–5 per cent because of issues with the Neptune observations. Based on application of the flux calibration parameters to Neptune observations performed using typical scan map observing modes, we determined that measurements from each array as a whole have instrumental uncertainties of 1.5 per cent. This is considerably less than the absolute calibration uncertainty associated with the model of Neptune, which is estimated at 4 per cent.Keywords
This publication has 11 references indexed in Scilit:
- THE BOLOCAM GALACTIC PLANE SURVEY: λ = 1.1 AND 0.35 mm DUST CONTINUUM EMISSION IN THE GALACTIC CENTER REGIONThe Astrophysical Journal, 2010
- HerschelSpace ObservatoryAstronomy and Astrophysics, 2010
- TheHerschel-SPIRE instrument and its in-flight performanceAstronomy and Astrophysics, 2010
- Thermal illuminators for far-infrared and submillimeter astronomical instrumentsApplied Optics, 2005
- Silicon nitride micromesh bolometer array for submillimeter astrophysicsApplied Optics, 2001
- The Near-Millimeter Brightness Temperature Spectra of Uranus and NeptuneIcarus, 1993
- The atmosphere of Neptune - an analysis of radio occultation data acquired with Voyager 2The Astronomical Journal, 1992
- Submillimeter and millimeter observations of Uranus and NeptuneIcarus, 1986
- Far-infrared and submillimeter brightness temperatures of the giant planetsIcarus, 1985
- On the Apparent Disc and on the Shadow of an EllipsoidMonthly Notices of the Royal Astronomical Society, 1897