The endotracheal tube air leak test does not predict extubation outcome in critically ill pediatric patients
- 1 September 2008
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Pediatric Critical Care Medicine
- Vol. 9 (5), 490-496
- https://doi.org/10.1097/pcc.0b013e3181849901
Abstract
Objective: Endotracheal tube air leak pressures are used to predict postextubation upper airway compromise such as stridor, upper airway obstruction, or risk of reintubation. To determine whether the absence of an endotracheal tube air leak (air leak test ≥30 cm H2O) measured during the course of mechanical ventilation predicts extubation failure in infants and children. Design: Prospective, blinded cohort. Setting: Multidisciplinary pediatric intensive care unit of a university hospital. Patients: Patients younger than or equal to 18 yrs and intubated ≥24 hrs. Interventions: The pressure required to produce an audible endotracheal tube air leak was measured within 12 hrs of intubation and extubation. Unless prescribed by the medical care team, patients did not receive neuromuscular blocking agents during air leak test measurements. Measurements and Main Results: The need for reintubation (i.e., extubation failure) was recorded during the 24-hr postextubation period. Seventy-four patients were enrolled resulting in 59 observed extubation trials. The extubation failure rate was 15.3% (9 of 59). Seven patients were treated for postextubation stridor. Extubation failure was associated with a longer median length of ventilation, 177 vs. 78 hrs, p = 0.03. Extubation success was associated with the use of postextubation noninvasive ventilation (p = 0.04). The air leak was absent for the duration of mechanical ventilation (i.e., ≥30 cm H2O at intubation and extubation) in ten patients. Absence of the air leak did not predict extubation failure (negative predictive value 27%, 95% confidence interval 6–60). The air leak test was ≥30 cm H2O before extubation in 47% (28 of 59) of patients yet 23 patients extubated successfully (negative predictive value 18%). Conclusions: An endotracheal tube air leak pressure ≥30 cm H2O measured in the nonparalyzed patient before extubation or for the duration of mechanical ventilation was common and did not predict an increased risk for extubation failure. Pediatric patients who are clinically identified as candidates for an extubation trial but do not have an endotracheal tube air leak may successfully tolerate removal of the endotracheal tube. (Pediatr Crit Care Med 2008; 9:490–496)Keywords
This publication has 44 references indexed in Scilit:
- We need to predict extubation failureJornal de Pediatria, 2006
- Spontaneous breathing trial predicts successful extubation in infants and childrenPediatric Critical Care Medicine, 2006
- Uncuffed endotracheal tubes should not be used in seriously burned childrenPediatric Critical Care Medicine, 2006
- Optimally fitted tracheal tubes decrease the probability of postextubation adverse events in children undergoing general anesthesiaPediatric Anesthesia, 2006
- Extubation failure in pediatric intensive care incidence and outcomesPediatric Critical Care Medicine, 2005
- Extubation failure in pediatric intensive care: A multiple-center study of risk factors and outcomesCritical Care Medicine, 2003
- Is the Leak Test Reproducible?Southern Medical Journal, 2000
- Factors influencing acquired subgottic stenosis in infantsThe Journal of Pediatrics, 1986
- Factors affecting leak around tracheal tubes in childrenCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1985
- Endotracheal Tube Cuff Residual Volume and Lateral Wall Pressure in a Model TracheaAnesthesiology, 1981