Results from a multicentre comparison of cryoballoon vs. radiofrequency ablation for paroxysmal atrial fibrillation: is cryoablation more reproducible?
- 5 June 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (1), euw080-57
- https://doi.org/10.1093/europace/euw080
Abstract
Aim Cryoballoon ablation (Cryoballoon) has emerged as a new alternative for the treatment of symptomatic drug-refractory atrial fibrillation (AF). Whether the results of Cryoballoon are more reproducible than those of radiofrequency (RF) ablation remains to be proved. Methods and results A total of 860 consecutive patients undergoing a first ablation procedure for paroxysmal AF (467 treated with RF and 393 treated with Cryoballoon) were selected from a prospective multicentre survey of AF ablation (FrenchAF). Radiofrequency and Cryoballoon were compared regarding mid-term efficacy and safety. During a median follow-up of 14 months (interquartile range 8–23), patients treated with Cryoballoon displayed similar rates of freedom from atrial arrhythmia relapse in centres performing this technique (68–80% at 18 months). However, in centres performing RF, a greater heterogeneity in procedural results was observed (46–79% were free from atrial arrhythmia relapse at 18 months). On multivariate analysis, Cryoballoon (HR = 0.47, 95% CI 0.35–0.65, P < 0.001) and annual AF ablation caseload (HR = 0.87 per every 100 AF ablation procedures per year; 95% CI 0.80–0.96, P = 0.003) were independent predictors of procedural success. However, on sensitivity analysis, according to the ablation method, annual AF ablation caseload predicted only sinus rhythm maintenance in the subgroup of patients treated with RF. Analysis of interoperator results with Cryoballoon and RF confirmed lower reproducibility of RF, but suggested that besides caseload, other operator-related factors may play a role. Conclusion Cryoballoon seems to be less operator-dependent and more reproducible than RF in the setting of paroxysmal AF ablation.Keywords
This publication has 25 references indexed in Scilit:
- Rationale and Design of FIRE AND ICE: A Multicenter Randomized Trial Comparing Efficacy and Safety of Pulmonary Vein Isolation Using a Cryoballoon versus Radiofrequency Ablation with 3D‐ReconstructionJournal of Cardiovascular Electrophysiology, 2014
- Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial FibrillationJournal of the American College of Cardiology, 2013
- 2012 focused update of the ESC Guidelines for the management of atrial fibrillationEP Europace, 2012
- Radiofrequency Catheter Ablation and Antiarrhythmic Drug TherapyCirculation: Arrhythmia and Electrophysiology, 2011
- Comparison of Antiarrhythmic Drug Therapy and Radiofrequency Catheter Ablation in Patients With Paroxysmal Atrial FibrillationJama-Journal Of The American Medical Association, 2010
- Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcomeEuropean Heart Journal, 2007
- Efficacy and Safety of Circumferential Pulmonary Vein Isolation Using a Novel Cryothermal Balloon Ablation SystemJournal of the American College of Cardiology, 2005
- Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation, 2005
- Lifetime Risk for Development of Atrial FibrillationCirculation, 2004
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998