A compact and high sensitivity positron detector using dual-layer thin GSO scintillators for a small animal PET blood sampling system
- 15 June 2010
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (13), 3813-3826
- https://doi.org/10.1088/0031-9155/55/13/016
Abstract
For quantitative measurements of small animals such as mice or rats, a compact and high sensitivity continuous blood sampling detector is required because their blood sampling volume is limited. For this purpose we have developed and tested a new positron detector. The positron detector uses a pair of dual-layer thin gadolinium orthosilicate (GSO) scintillators with different decay times. The front layer detects the positron and the background gamma photons, and the back layer detects the background gamma photons. By subtracting the count rate of the latter from that of the former, the count rate of the positrons can be estimated. The GSO for the front layer has a Ce concentration of 1.5 mol% (decay time of 35 ns), and that for the back layer has a Ce concentration of 0.5 mol% (decay time of 60 ns). By using the pulse shape analysis, the count rate of these two GSOs can be discriminated. The thickness is 0.5 mm, which is thick enough to detect positrons while minimizing the detection of the background gamma photons. These two types of thin GSOs were optically coupled to each other and connected to a metal photomultiplier tube (PMT) through triangular light guides. The signal from the PMT was digitized by 100 MHz free-running A-D converters in the data acquisition system and digitally integrated at two different integration times for the pulse shape analysis. We obtained good separation of the pulse shape distributions of these two GSOs. The energy threshold level was decreased to 80 keV, increasing the sensitivity of the detector. The sensitivity of a small diameter plastic tube was 8.6% and 24% for the F-18 and C-11 positrons, respectively. The count rate performance was linear up to approximately 50 kcps. The background counts from the gamma photons could be precisely corrected. The time-activity curve (TAC) of the rat artery blood was successfully obtained and showed a good correlation with that measured using a well counter. With these results, we confirmed that the developed blood sampling detector is promising for quantitative measurement for an animal positron emission tomography system.This publication has 14 references indexed in Scilit:
- Estimation of the 18F-FDG Input Function in Mice by Use of Dynamic Small-Animal PET and Minimal Blood Sample DataJournal of Nuclear Medicine, 2007
- A New Tool for Molecular Imaging: The Microvolumetric Blood CounterJournal of Nuclear Medicine, 2007
- The application of maximum likelihood factor analysis (MLFA) with uniqueness constraints on dynamic cardiac microPET dataPhysics in Medicine & Biology, 2007
- Development of a GSO detector assembly for a continuous blood sampling systemIEEE Transactions on Nuclear Science, 2003
- Removal of blood from laboratory mammals and birds: First Report of the BVA/FRAME/RSPCA/UFAW Joint Working Group on RefinementLaboratory Animals, 1993
- Cerium doped GSO scintillators and its application to position sensitive detectorsIEEE Transactions on Nuclear Science, 1989
- Biological Effects of Blood Loss: Implications for Sampling Volumes and Techniques * Commentary: H. Richard AdamsILAR Journal, 1989
- Automated blood sampling systems for positron emission tomographyIEEE Transactions on Nuclear Science, 1988
- A System for Cerebral Blood Flow Measurement Using an H215O Autoradiographic Method and Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1987
- A Continuous Flow Input Function Detector for H2 15O Blood Flow Studies in Positron Emission TomographyIEEE Transactions on Nuclear Science, 1986