Heat conduction from the exceedingly hot fiber tip contributes to the endovenous laser ablation of varicose veins
Open Access
- 14 February 2009
- journal article
- Published by Springer Science and Business Media LLC in Lasers in Medical Science
- Vol. 24 (2), 247-251
- https://doi.org/10.1007/s10103-008-0639-y
Abstract
Lower-extremity venous insufficiency is a common condition, associated with considerable health care costs. Endovenous laser ablation is increasingly used as therapy, but its mechanism of action is insufficiently understood. Here, direct absorption of the laser light, collapsing steam bubbles and direct fiber-wall contact have all been mentioned as contributing mechanisms. Because fiber tips have reported temperatures of 800–1,300°C during endovenous laser ablation, we sought to assess whether heat conduction from the hot tip could cause irreversible thermal injury to the venous wall. We approximated the hot fiber tip as a sphere with diameter equal to the fiber diameter, having a steady state temperature of 800°C or 1,000°C. We computed venous wall temperatures due to heat conduction from this hot sphere, varying the pullback velocity of the fiber and the diameter of the vein. Venous wall temperatures corresponding to irreversible injury resulted for a 3 mm diameter vein and pullback velocities <3 mm/s but not for 5 mm and ≥1 mm/s. The highest wall temperature corresponded to the position on the wall closest to the fiber tip, hence it moves longitudinally in parallel with the moving fiber tip. We concluded that heat conduction from the hot fiber tip is a contributing mechanism in endovenous laser ablation.Keywords
This publication has 17 references indexed in Scilit:
- Endovenous Laser Ablation–Induced Complications: Review of the Literature and New CasesDermatologic Surgery, 2009
- Endovenous therapies of lower extremity varicosities: A meta-analysisJournal of Vascular Surgery, 2009
- Endovenous laser ablation: mechanism of actionPhlebology: The Journal of Venous Disease, 2008
- Mathematical modeling of 980‐nm and 1320‐nm endovenous laser treatmentLasers in Surgery and Medicine, 2007
- Endovascular Treatment of Varicose VeinsSeminars in Vascular Surgery, 2006
- Endovenous Ablation of Incompetent Saphenous Veins:A Large Single-Center ExperienceJournal of Endovascular Therapy, 2006
- Systematic review of endovenous laser treatment for varicose veinsBritish Journal of Surgery, 2005
- Comparison of Endovenous Radiofrequency Versus 810 nm Diode Laser Occlusion of Large Veins in an Animal ModelDermatologic Surgery, 2002
- Optical Properties of Circulating Human Blood in the Wavelength Range 400–2500 nmJournal of Biomedical Optics, 1999
- Temperature along the surface of modified fiber tips for Nd:YAG laser angioplastyLasers in Surgery and Medicine, 1991