Validation of a New Model-Based Tracking Technique for Measuring Three-Dimensional, In Vivo Glenohumeral Joint Kinematics
Open Access
- 31 January 2006
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 128 (4), 604-609
- https://doi.org/10.1115/1.2206199
Abstract
Shoulder motion is complex and significant research efforts have focused on measuring glenohumeral joint motion. Unfortunately, conventional motion measurement techniques are unable to measure glenohumeral joint kinematics during dynamic shoulder motion to clinically significant levels of accuracy. The purpose of this study was to validate the accuracy of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. We have developed a model-based tracking technique for accurately measuring in vivo joint motion from biplane radiographic images that tracks the position of bones based on their three-dimensional shape and texture. To validate this technique, we implanted tantalum beads into the humerus and scapula of both shoulders from three cadaver specimens and then recorded biplane radiographic images of the shoulder while manually moving each specimen’s arm. The position of the humerus and scapula were measured using the model-based tracking system and with a previously validated dynamic radiostereometric analysis (RSA) technique. Accuracy was reported in terms of measurement bias, measurement precision, and overall dynamic accuracy by comparing the model-based tracking results to the dynamic RSA results. The model-based tracking technique produced results that were in excellent agreement with the RSA technique. Measurement bias ranged from −0.126to0.199mm for the scapula and ranged from −0.022to0.079mm for the humerus. Dynamic measurement precision was better than 0.130mm for the scapula and 0.095mm for the humerus. Overall dynamic accuracy indicated that rms errors in any one direction were less than 0.385mm for the scapula and less than 0.374mm for the humerus. These errors correspond to rotational inaccuracies of approximately 0.25deg for the scapula and 0.47deg for the humerus. This new model-based tracking approach represents a non-invasive technique for accurately measuring dynamic glenohumeral joint motion under in vivo conditions. The model-based technique achieves accuracy levels that far surpass all previously reported non-invasive techniques for measuring in vivo glenohumeral joint motion. This technique is supported by a rigorous validation study that provides a realistic simulation of in vivo conditions and we fully expect to achieve these levels of accuracy with in vivo human testing. Future research will use this technique to analyze shoulder motion under a variety of testing conditions and to investigate the effects of conservative and surgical treatment of rotator cuff tears on dynamic joint stability.Keywords
This publication has 63 references indexed in Scilit:
- Kinematics of the ACL‐deficient canine knee during gait: Serial changes over two yearsJournal of Orthopaedic Research, 2004
- The effect of capsular tightening on humeral head translationsJournal of Orthopaedic Research, 2004
- Dynamic contributions to superior shoulder stabilityJournal of Orthopaedic Research, 2001
- Kinematic comparisons of 1996 Olympic baseball pitchersJournal of Sports Sciences, 2001
- Calibration of the “Flock of Birds” electromagnetic tracking device and its application in shoulder motion studiesJournal of Biomechanics, 1999
- Translation of the glenoihumeral joint with the patient under anesthesiaJournal of Shoulder and Elbow Surgery, 1996
- Radiologic measurement of superior displacement of the humeral head in the impingement syndromeJournal of Shoulder and Elbow Surgery, 1996
- A new dynamic testing apparatus to study glenohumeral joint motionJournal of Biomechanics, 1995
- A dynamic shoulder model: Reliability testing and muscle force studyJournal of Biomechanics, 1995
- Three‐dimensional kinematics of glenohumeral elevationJournal of Orthopaedic Research, 1991