Abstract
Object: Internal MRI coils have important applications in diagnostic and interventional studies. Since they can be placed very close to the region of interest in the body, they are favored over external coils in applications where high-resolution images are required. In this paper it is demonstrated that ultimate intrinsic SNR (UISNR) and the optimum coil sensitivity solutions can be used to make new coil designs with higher intrinsic SNR. Materials and methods: In this study, UISNR, which is the maximum attainable value of the intrinsic SNR, is used as a measure of performance and as a design criterion. As an example, a novel endorectal MRI coil is designed. The design is tested with phantom and patient studies. Results: An endorectal coil is built to demonstrate the effectiveness of the design strategy. ISNR of the endorectal coil approximates the UISNR to 72%. Conclusion: An internal coil design method that takes advantage of the UISNR and optimum coil sensitivity calculations was presented. This method can also be used to design better internal MRI coils for different applications. © 2009 ESMRMBKeywords
This publication has 14 references indexed in Scilit:
- The signal-to-noise ratio of the nuclear magnetic resonance experimentJournal of Magnetic Resonance, 2011
- Design of a Novel MRI Compatible Manipulator for Image Guided Prostate InterventionsIEEE Transactions on Biomedical Engineering, 2005
- Evaluation of internal MRI coils using ultimate intrinsic SNRMagnetic Resonance in Medicine, 2004
- Phased-array MRI of canine prostate using endorectal and endourethral coilsMagnetic Resonance in Medicine, 2003
- A nonparametric method for automatic correction of intensity nonuniformity in MRI dataIEEE Transactions on Medical Imaging, 1998
- Intravascular magnetic resonance imaging using a loopless catheter antennaMagnetic Resonance in Medicine, 1997
- Retrospective correction of intensity inhomogeneities in MRIIEEE Transactions on Medical Imaging, 1995
- Intravascular (catheter) NMR receiver probe: Preliminary design analysis and application to canine iliofemoral imagingMagnetic Resonance in Medicine, 1992
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986
- The signal-to-noise ratio of the nuclear magnetic resonance experimentJournal of Magnetic Resonance (1969), 1976