Termination of Atrial Fibrillation Using Pulsed Low-Energy Far-Field Stimulation
- 11 August 2009
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Circulation
- Vol. 120 (6), 467-476
- https://doi.org/10.1161/circulationaha.108.825091
Abstract
Background— Electrically based therapies for terminating atrial fibrillation (AF) currently fall into 2 categories: antitachycardia pacing and cardioversion. Antitachycardia pacing uses low-intensity pacing stimuli delivered via a single electrode and is effective for terminating slower tachycardias but is less effective for treating AF. In contrast, cardioversion uses a single high-voltage shock to terminate AF reliably, but the voltages required produce undesirable side effects, including tissue damage and pain. We propose a new method to terminate AF called far-field antifibrillation pacing, which delivers a short train of low-intensity electric pulses at the frequency of antitachycardia pacing but from field electrodes. Prior theoretical work has suggested that this approach can create a large number of activation sites (“virtual” electrodes) that emit propagating waves within the tissue without implanting physical electrodes and thereby may be more effective than point-source stimulation. Methods and Results— Using optical mapping in isolated perfused canine atrial preparations, we show that a series of pulses at low field strength (0.9 to 1.4 V/cm) is sufficient to entrain and subsequently extinguish AF with a success rate of 93% (69 of 74 trials in 8 preparations). We further demonstrate that the mechanism behind far-field antifibrillation pacing success is the generation of wave emission sites within the tissue by the applied electric field, which entrains the tissue as the field is pulsed. Conclusions— AF in our model can be terminated by far-field antifibrillation pacing with only 13% of the energy required for cardioversion. Further studies are needed to determine whether this marked reduction in energy can increase the effectiveness and safety of terminating atrial tachyarrhythmias clinically.Keywords
This publication has 43 references indexed in Scilit:
- Evaluating Intramural Virtual Electrodes in the Myocardial Wedge Preparation: Simulations of Experimental ConditionsBiophysical Journal, 2008
- Quantification of Shock‐Induced Microscopic Virtual Electrodes Assessed by Subcellular Resolution Optical Potential Mapping in Guinea Pig Papillary MuscleJournal of Cardiovascular Electrophysiology, 2007
- A randomized trial comparing monophasic and biphasic waveform shocks for external cardioversion of atrial fibrillationAmerican Heart Journal, 2004
- Effects of electroporation on optically recorded transmembrane potential responses to high-intensity electrical shocksAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Atrial FibrillationCirculation, 2002
- Clinical efficacy and safety of atrial defibrillation using biphasic shocks and current nonthoracotomy endocardial lead configurationsThe American Journal of Cardiology, 1995
- Efficacy and tolerability of transvenous low energy cardioversion of paroxysmal atrial fibrillation in humansJournal of the American College of Cardiology, 1995
- Initial Experience with Intracardiac Atrial Defibrillation in Patients with Chronic Atrial FibrillationPacing and Clinical Electrophysiology, 1994
- Intra-atrial reentry as a mechanism for atrial flutter induced by acetylcholine and rapid pacing in the dog.Circulation, 1984
- The nature of sources of bioelectric and biomagnetic fieldsBiophysical Journal, 1982